A New Suppression Index Calculation Using the Visually Enhanced Vestibulo-Ocular Reflex and Vestibulo-Ocular Reflex Suppression Paradigms in the Video Head Impulse Test

Author:

Prieto-Matos Carlos1ORCID,Rey-Martínez Jorge2ORCID,Pérez-Fernández Nicolás3ORCID

Affiliation:

1. ENT Department, Clínica Universidad de Navarra, 31008 Pamplona, Spain

2. Neurotology Unit, ENT Department, Hospital Universitario Donostia, 20014 Donostia-San Sebastián, Spain

3. ENT Department, Clínica Universidad de Navarra, 28027 Madrid, Spain

Abstract

The aim of this study is to calculate the gains of the quantified visually enhanced vestibulo-ocular reflex (qVVOR) and the quantified vestibulo-ocular reflex suppression (qVORS), using a specific system to generate a visual suppression index (SI) in healthy subjects obtained through the gains of qVVOR and qVORS, and to determine the normal values of the index, as well as the influence of age and sex variables on the SI. Methods. This prospective observational clinical study includes 83 healthy subjects who underwent the head impulse and suppression tests (HIMP and SHIMP, respectively), qVVOR, and qVORS tests, all of the vHIT. The sinusoidal tests (qVVOR and qVORS) were conducted at an intended frequency of 0.75 Hz. The gains of these tests were calculated using a system specifically designed for this purpose. A formula for the SI was established using a ratio of the gains from these tests. Two SI values are presented: unilateral, distinct for each direction of head movement, and bilateral, representing the suppression of both sides simultaneously. Results. Mean gains for the qVVORs were 0.981 ± 0.070 and 0.978 ± 0.077 for the rightwards and leftwards qVVORs, respectively. The gains for the suppressed tests were 0.334 ± 0.112 and 0.353 ± 0.110 for the rightwards and leftwards qVORSs, respectively. A difference of 0.05 Hz was observed between the expected (0.75 Hz) and the obtained frequency of head movement, which is statistically significant (p < 0.001). The SI was 0.342 ± 0.118 for the right side (right SI) and 0.363 ± 0.117 for the left side (left SI). The bilateral SI had a mean value of 0.295 ± 0.104. No significant differences in the SI were noted according to the subject’s age. The SI for women was lower than in the case of males. Conclusions: The VVOR/VORS quantification algorithm allows for the reliable calculation of the numerical gain of qVVOR and qVORS with mathematical soundness and consistency of results. Our data support the use of a single or specific measure for direction of head movement; although significant differences exist, these differences are not clinically relevant.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3