The Reliability of ClinCheck® Accuracy before and after Invisalign® Treatment—A Multicenter Retrospective Study

Author:

Alswajy Wafa1ORCID,Baeshen Hosam1,Al-Turki Ghassan1ORCID,Alsulaimani Fahad1ORCID

Affiliation:

1. Department of Orthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia

Abstract

The objective was to evaluate the accuracy of ClinCheck® reliability in the sagittal, vertical, transverse, and arch length dimensions before and after Invisalign® (Align Technology, Santa Clara, CA, USA) treatment. This retrospective study was conducted on 206 patients who underwent dual-arch clear aligner therapy exclusively with Invisalign®. Digital models were obtained from iTero® scanners from three different private practices where the treatment plans were performed and executed by multiple orthodontists with varying degrees of experience. The ClinCheck® models of the initial, achieved, and predicted outcome were obtained from Align Technology® and the values were compared using Pearson correlation (p < 0.05) to determine if predicted values were correlated with achieved values. ANOVA was used to compare the different centers. The highest reliabilities were associated with interincisal angle (96.23%), upper intercanine width (97.97%), lower intercanine width (97.67%), upper intermolar width (97.58%), and lower intermolar width (97.72%) (p < 0.001). The lowest reliabilities were associated with arch length parameters in which the upper was 38.79% and the lower at 30.02% (p = 0.03, p < 0.001). However, there were no statistically significant differences between the centers in terms of the accuracy of treatment provided. The mean predicted accuracy of Invisalign® was 76.85% overall; however, Invisalign® providers may need to exaggerate the digital tooth movements to achieve the desired outcome.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Reference26 articles.

1. Complex orthodontic treatment using a new protocol for the Invisalign appliance;Boyd;J. Clin. Orthod.,2007

2. Invisalign eighth-generation features for deep-bite correction and posterior arch expansion;Moshiri;Semin. Orthod.,2021

3. Clinical effectiveness of orthodontic miniscrew implants: A meta-analysis;Papadopoulos;J. Dent. Res.,2011

4. Effectiveness of clear aligner therapy for orthodontic treatment: A systematic review;Robertson;Orthod. Craniofac. Res.,2020

5. Efficacy of clear aligners in controlling orthodontic tooth movement: A systematic review;Rossini;Angle Orthod.,2015

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3