Investigation of Stent Prototypes for the Eustachian Tube in Human Donor Bodies

Author:

Rosenbusch Lena1,Schuon Robert1ORCID,Wilfling Tamara1,Krüger Philipp2,Lebahn Kerstin3,John Samuel4ORCID,Sahmel Olga3,Grabow Niels3,Schulze Marko5ORCID,Wree Andreas5,Schmitz Klaus-Peter3,Stein Tobias2,Lenarz Thomas16ORCID,Paasche Gerrit16

Affiliation:

1. Department of Otorhinolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany

2. Bess Pro GmbH, Gustav-Krone-Str. 7, 14167 Berlin, Germany

3. Institute for Biomedical Engineering, Rostock University Medical Center, 18119 Rostock, Germany

4. HörSys GmbH, 30625 Hannover, Germany

5. Institute of Anatomy, Rostock University Medical Center, 18057 Rostock, Germany

6. Cluster of Excellence Hearing4all, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany

Abstract

Chronic otitis media is often connected to Eustachian tube dysfunction. As successful treatment cannot be guaranteed with the currently available options, the aim is to develop a stent for the Eustachian tube (ET). Over the course of this development, different prototypes were generated and tested in ex vivo experiments. Four different prototypes of an ET stent and one commercially available coronary stent were implanted in the ET of seven human donor bodies. The position of the stents was verified by cone beam CT. The implanted ETs were harvested, embedded in resin and ground at 200 µm steps. Resulting images of the single steps were used to generate 3D models. The 3D models were then evaluated regarding position of the stent in the ET, its diameters, amount of squeezing, orientation of the axes and other parameters. Virtual reconstruction of the implanted ET was successful in all cases and revealed one incorrect stent placement. The cross-section increased for all metal stents in direction from the isthmus towards the pharyngeal orifice of the ET. Depending on the individual design of the metal stents (open or closed design), the shape varied also between different positions along a single stent. In contrast, the cross-section area and shape remained constant along the polymeric prototype. With the current investigation, insight into the behavior of different prototypes of ET stents was gained, which can help in defining the specifications for the intended ET stent.

Funder

German Ministry for Education and Research

Publisher

MDPI AG

Subject

Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3