A Retrospective Study on the Transferring Accuracy of a Fully Guided Digital Template in the Anterior Zone

Author:

Huang Lirong,Zhang Xiaoqing,Mo Anchun

Abstract

The accuracy of implant placement with a fully guided digital template can be influenced by many factors, such as arch difference, alveolar bone density, timing of implant placement and open flap. The purpose of this article was to evaluate the factors presumptively affecting the accuracy of implant placement assisted by the fully guided template in the anterior zone. In 40 patients with missing anterior teeth, a total of 52 implants were placed with tooth-borne, fully guided templates after CBCT evaluation, in West China Hospital of Stomatology, Sichuan University. After overlapping the pre-and post-operative DICOM data, measurements were taken in the dental implant planning software (Nobel Clinician®) to calculate linear and angular deviations between virtual placement plan and actual implant placement. Grouping was categorized according to three factors that possibly have an influence on accuracy: arch type (maxilla/mandible), timing of implant placement (immediate/delayed), surgical technique (open flap/flapless). The data was analyzed with independent sample t-test (p < 0.05). The results showed that the apical, coronal, depth and angular mean deviations of implant positions in anterior zone were 1.13 ± 0.39 mm, 0.86 ± 0.33 mm, 0.41 ± 0.66 mm, 3.32 ± 1.65° with the fully guided templates. The accuracy at apex level, coronal level and the angulation were similar between the maxilla and mandible, and the magnitude of all four deviations between immediate and delayed implantation, open flap and flapless technique were small. No statistically significant difference was observed (p > 0.05). Whereas there was significant difference in depth deviation between maxilla and mandible (p < 0.05). Conclusively, the implant site, alveolar bone density, timing of implant placement and surgical techniques merely compromise the implant placement accuracy under the assistance of a fully guided template.

Publisher

MDPI AG

Subject

General Materials Science

Reference61 articles.

1. Optimizing esthetics for implant restorations in the anterior maxilla: Anatomic and surgical considerations;Buser;Int. J. Oral Maxillofac. Implant.,2004

2. Clinical Accuracy of 3 Different Types of Computed Tomography-Derived Stereolithographic Surgical Guides in Implant Placement

3. Accuracy of computer-aided oral implant surgery: A clinical and radiographic study;Valente;Int. J. Oral Maxillofac. Implant.,2009

4. Accuracy of Two Stereolithographic Guide Systems for Computer-Aided Implant Placement: A Computed Tomography-Based Clinical Comparative Study

5. Surgical guide for dental implant placement

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3