Experimental Investigation on the Axial Compressive Behaviour of Cold-Formed Steel-Concrete Composite Columns Infilled with Various Types of Fibre-Reinforced Concrete

Author:

More Florence More Dattu Shanker,Subramanian Senthil Selvan

Abstract

The exceptional structural strength and low cost of steel-concrete composite columns make them a popular choice for civil engineering structures. Numerous forms of composite columns, including steel tubes filled with concrete, have been produced recently in response to various construction situations. Cold-formed steel tubular columns with concrete filling have higher strength and ductility due to their capacity to withstand inner buckling and postpone outward buckling. The objective of this research is to determine the ductile and strength performance of composite columns containing various forms of fibre-reinforced concrete when subjected to axial compression. Several different kinds of fibre-reinforced concrete (FRC) are employed as additives in hollow steel columns, including steel FRC, carbon FRC, glass FRC, coir FRC, jute FRC, and sisal FRC. Axial compression tests were performed on 24 columns, including three hollow steel columns and 21 composite columns. Three distinct slenderness ratios were developed and used. Axial bearing capacity, compressive stress-strain curves, ductility, peak strain, axial shortening, and toughness were among the topics covered by the axial compression test. Experimental findings demonstrated that all conventional composite columns experienced failure through overall buckling, Local buckling and crushing of concrete infill, which was transformed into more ductile failure using fibre-reinforced concrete infills. The test results revealed that fibre-reinforced concrete-infilled steel columns outperformed conventional composite columns in terms of strength, ductility, and energy absorption capacity. The percentage increase in load-carrying capacity was observed as 203.88%, 193.48% and 190.03% when compared to hollow cold-formed steel tubular columns in medium, short and stub columns, respectively. Under assessment of stub, short, and medium columns, the load-strain plots demonstrated that the steel fibre-reinforced concrete in-filled columns performed well in terms of ductility. Localized buckling and crushing of the concrete infill caused the composite columns with low slenderness ratios to fail. In contrast, concrete-filled steel tube columns with higher slenderness ratios showed column failure through the overall buckling of the composite column.

Publisher

MDPI AG

Subject

Building and Construction,Civil and Structural Engineering,Architecture

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3