Affiliation:
1. School of Architecture, University of Navarra, 31009 Pamplona, Spain
2. School of Technology, Universidad de Extremadura, 10003 Cáceres, Spain
Abstract
The current decarbonization transition to be achieved by 2050 according to the European Council has given great prominence to the use of Digital Twins as tools for energy management. For their correct operation, it is essential to control the uncertainties of the energy models, which lead to differences between the measured and predicted data. One of the key parameters that is most difficult to assess numerically is air leakage. The existent infiltration models available in EnergyPlus were developed to be applied in low-rise residential buildings with fewer than three stories. Therefore, it is common to rely on air leakage equations employing predefined coefficients. This research presents an empirical assessment of the performance of two EnergyPlus air leakage models, the “Effective Leakage Area” and the “Flow Coefficient”, in predicting dynamic infiltration within the attic of a seven-story building. Blower door tests, along with the application of CO2 tracer gas, were conducted to establish coefficients for the models. Then, they were evaluated in three independent periods according to the criteria established in the American Society for Testing Material D5157 Standard. Those models that only used in situ coefficients consistently met the standard across all three periods, demonstrating for both equations their accurate performance and reliability. For the best model derived from tracer gas data, the R2 and NMSE values are 0.94 and 0.019, respectively. In contrast, the model developed using blower door test data and EnergyPlus default values presented a 64% reduction in accuracy compared to the best one. This discrepancy could potentially lead to misleading energy estimates. Although other software options exist for estimating infiltration, this study specifically targets EnergyPlus users. Therefore, these findings offer valuable insights to make more informed decisions when implementing the infiltration models into energy simulations for high-rise buildings using EnergyPlus.
Funder
“Asociación de Amigos de la Universidad de Navarra” of the University of Navarra, Spain
Reference69 articles.
1. European Commission and Directorate-General for Energy (2019). Clean Energy for All Europeans, European Commission. Technical Report.
2. European Commission (2020). COM(2020) 562 Final: Stepping up Europe’s 2030 Climate Ambition. Investing in a Climate-Neutral Future for the Benefit of Our People, Technical Report.
3. Hou, L., Wu, S., Zhang, G., Tan, Y., and Wang, X. (2020). Literature review of digital twins applications in construction workforce safety. Appl. Sci., 11.
4. Review of digital twin about concepts, technologies, and industrial applications;Liu;J. Manuf. Syst.,2021
5. Tahmasebinia, F., Lin, L., Wu, S., Kang, Y., and Sepasgozar, S. (2023). Exploring the Benefits and Limitations of Digital Twin Technology in Building Energy. Appl. Sci., 13.