External Wall Systems in Passive House Standard: Material, Thermal and Environmental LCA Analysis

Author:

Mazur Łukasz12ORCID,Szlachetka Olga3ORCID,Jeleniewicz Katarzyna3ORCID,Piotrowski Michał1ORCID

Affiliation:

1. Łukasiewicz Research Network-Institute of Electrical Engineering, Mieczysława Pożaryskiego 28, 04-703 Warszawa, Poland

2. Faculty of Engineering, Helena Chodkowska University of Technology and Economics, Jagiellońska 82f, 03-301 Warsaw, Poland

3. Institute of Civil Engineering, Warsaw University of Life Sciences, Nowoursynowska 159, 02-776 Warsaw, Poland

Abstract

The construction sector, a significant consumer of energy, possesses the potential to realize substantial environmental and economic advantages through the adoption of innovative technologies and design approaches. Notably, the Passive House standard, exemplified by energy-efficient single-family homes, emerges as a prominent solution. This study analyzes five external wall systems across multiple stages: (i) a literature review and examination of external wall techniques within the passive standard, utilizing the Passive House Database; (ii) a material and technological assessment of three wood-based and two masonry constructions; (iii) an in-depth thermal performance analysis of selected external partitions; and (iv) a Life Cycle Assessment (LCA) of the external wall systems. Our findings indicate that among the single-family homes built to the passive standard, 50.94% utilized timber constructions, while 34.21% employed masonry. Thermal analysis revealed that the masonry wall, EW-M-01, exhibited superior thermal efficiency with a heat transfer coefficient (U-value) of 0.0889 W/m2K. Meanwhile, the wooden wall, EW-T-01, led its category with a U-value of 0.1000 W/m2K. The LCA highlighted that the wooden wall EW-T-02 presented the lowest integrated non-renewable energy demand (PENTR) at 425.70 MJ/kg and the most favorable Global Warming Potential (GWP), with a reduction of 55.51 kg CO2e. Conversely, the masonry wall EW-M-01 recorded the highest energy demand and CO2e emissions, at 780.96 MJ/kg and 90.59 kg CO2e, respectively. Water consumption was lowest for the EW-T-02 wooden wall (0.08 m3) and highest for the EW-M-02 masonry wall (0.19 m3). Conclusively, our analysis of passive house external walls demonstrates that wood-based systems offer superior performance in terms of materials, thermal efficiency, and LCA indicators, positioning them as the preferred option for sustainable passive construction.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3