Vagus Nerve Stimulation in the Carotid Triangle: An Effective Method for Monitoring the Recurrent Laryngeal Nerve in Thyroid and Parathyroid Surgery

Author:

Traba Alfredo1,de Abreu Angela1,Nevado Clara2,Duran Hipólito3,Gil Antonio4,Pérez Seoane María4,Lopez-Gonzalez Laura56,Ortega Miguel A.57ORCID,Álvarez-Mon Melchor68,Martin Pedro4,San Roman Juan9,Díaz-Pedrero Raul5610ORCID

Affiliation:

1. Neurology and Neurophysiology, Hospital Universitario HM Sanchinarro, C/de Oña 10, 28050 Madrid, Spain

2. Neurology and Neurophysiology, Hospital Fundación Alcorcón, C/Budapest 1, 28922 Madrid, Spain

3. General and Digestive Surgery Department, Hospital Universitario HM Sanchinarro, C/Oña 10, 28050 Madrid, Spain

4. General and Digestive Surgery Department, Hospital Universitario HM Montepríncipe, Av. de Montepríncipe 25, 28660 Madrid, Spain

5. Ramón y Cajal Institute of Sanitary Research (IRYCIS), 28034 Madrid, Spain

6. Department of Surgery, Medical and Social Sciences, Faculty of Medicine and Health Sciences, University of Alcalá, 28801 Alcala de Henares, Spain

7. Department of Medicine and Medical Specialities, Faculty of Medicine and Health Sciences, University of Alcalá, 28801 Alcalá de Henares, Spain

8. Immune System Diseases-Rheumatology and Internal Medicine Service, University Hospital Prince of Asturias, Networking Research Center on for Liver and Digestive Diseases (CIBEREHD), 28806 Alcalá de Henares, Spain

9. General and Digestive Surgery Department, Hospital Universitario HM Torrelodones, Av. Castillo Olivares s/n, 28250 Madrid, Spain

10. General and Digestive Surgery Department, Hospital Universitario HM Rivas Vaciamadrid, 28521 Madrid, Spain

Abstract

Objective: Our objective is the description of the technique of vagus nerve stimulation in carotid triangle in order to monitor the recurrent laryngeal nerve (RLN) during thyroid and parathyroid surgery. Methods: We stimulated the vagus nerve in the carotid triangle during 150 thyroid or parathyroid surgeries using a monopolar electromyography electrode inserted under the mastoid process towards the jugular foramen as a cathode, and using another subdermal electrode in the mastoid as an anode. Another complementary method of vagus stimulation was achieved with a pair of subdermal electrodes, placing the cathode at the mandibular angle and the anode at the mastoid. Results: In all patients, compound muscle action potential (CMAP) was recorded in the vocal cords with both stimulation techniques, allowing semi-continuous monitoring to be carried out. Intraoperative lesions were detected in 16 of the cases; 9 of them were transient with CMAP recovery achieved when modifying surgical maneuvers. Conclusions: Vagus nerve stimulation in the carotid triangle is a reliable technique for monitoring the RLN in thyroid surgery. Vagus nerve stimulation in the carotid triangle is effective and safe for RLN monitoring, and it is a clear alternative to direct continuous stimulation of the nerve that by contrast requires its dissection in the carotid sheath.

Funder

Madrid’s community

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3