Bismuth Shielding in Head Computed Tomography—Still Necessary?

Author:

Di Rosso Jana1,Krasser Andreas2,Tschauner Sebastian1ORCID,Guss Helmuth2ORCID,Sorantin Erich1ORCID

Affiliation:

1. Division of Paediatric Radiology, Department of Radiology, Medical University of Graz, 8036 Graz, Austria

2. Competence Centre for Medical Physics and Radiation Protection, University Hospital Graz, 8036 Graz, Austria

Abstract

Introduction: Cranial CT scans are associated with radiation exposure to the eye lens, which is a particularly radiosensitive organ. Children are more vulnerable to radiation than adults. Therefore, it is essential to use the available dose reduction techniques to minimize radiation exposure. According to the European Consensus on patient contact shielding by the IRCP from 2021, shielding is not recommended in most body areas anymore. This study aims to evaluate whether bismuth shielding as well as its combination with other dose-saving technologies could still be useful. Methods: Cranial CT scans of a pediatric anthropomorphic phantom were performed on two up-to-date MDCT scanners. Eye lens dose measurements were performed using thermoluminescent dosimeters. Furthermore, the impact of BS and of the additional placement of standoff foam between the patient and BS on image quality was also assessed. Results: Bismuth shielding showed a significant lens dose reduction in both CT scanners (GE: 41.50 ± 4.04%, p < 0.001; Siemens: 29.75 ± 6.55%, p = 0.00). When combined with AEC, the dose was lowered even more (GE: 60.75 ± 3.30%, p < 0.001; Siemens: 41.25 ± 8.02%, p = 0.00). The highest eye dose reduction was achieved using BS + AEC + OBTCM (GE: 71.25 ± 2.98%, p < 0.001; Siemens: 58.75 ± 5.85%, p < 0.001). BS caused increased image noise in the orbital region, which could be mitigated by foam placement. Eye shielding had no effect on the image noise in the cranium. Conclusions: The use of BS in cranial CT can lead to a significant dose reduction, which can be further enhanced by its combination with other modern dose reduction methods. BS causes increase in image noise in the orbital region but not in the cranium. The additional use of standoff foam reduces image noise in the orbital region.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3