Comparison of Wireless Continuous Axillary and Core Temperature Measurement after Major Surgery

Author:

Nathansen Anders Blom1,Mølgaard Jesper1,Meyhoff Christian Sylvest23,Aasvang Eske Kvanner13

Affiliation:

1. Department of Anesthesiology, Center for Cancer and Organ Diseases, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2200 Copenhagen, Denmark

2. Department of Anesthesia and Intensive Care, Bispebjerg Hospital, University of Copenhagen, 2400 Copenhagen, Denmark

3. Department of Clinical Medicine, University of Copenhagen, 2200 Copenhagen, Denmark

Abstract

Background: Temperature is considered one of the primary vital signs for detection of complications such as infections. Continuous wireless real-time axillary temperature monitoring is technologically feasible at the general ward, but no clinical validation studies exist. Methods: This study compared axillary temperature with a urinary bladder thermometer in 40 major abdominal postoperative patients. The primary outcome was changes in axillary temperature registrations. Secondary outcomes were mean bias between the urinary bladder and the axillary temperatures. Intermittent frontal and tympanic temperature recordings were also collected. Results: Forty patients were monitored for 50 min with an average core temperature of 36.8 °C. The mean bias was −1.0 °C (LoA −1.9 to −0) after 5 min, and −0.8 °C (LoA −1.6 to −0.1) after 10 min when comparing the axillary temperature with the urinary bladder temperature. After 20 min, the mean bias was −0.6 °C (LoA −1.3–0.1). During upper arm abduction, the axilla temperature was reduced to −1.6 °C (LoA −2.9 to −0.3) within 1 min. Temporal skin temperature measurement had a resulted in a mean bias of −0.1 °C (LOA −1.1 to −1.0) compared with central temperature. Compared with the mean tympanic temperature, it was −0.1 °C (LoA −0.9 to −1.0) lower than the urinay bladder temperature. Conclusions: Axillary temperature increased with time, reaching a mean bias of 1 °C between axillary and core temperature within 5 min. Opening the axillary resulted in rapidly lower temperature recordings. These findings may aid in use and designing corrections for continuous axillary temperature monitoring.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3