Simulation Study of a Frame-Based Motion Correction Algorithm for Positron Emission Imaging

Author:

Espinós-Morató HéctorORCID,Cascales-Picó DavidORCID,Vergara MarinaORCID,Hernández-Martínez ÁngelORCID,Benlloch Baviera José MaríaORCID,Rodríguez-Álvarez María JoséORCID

Abstract

Positron emission tomography (PET) is a functional non-invasive imaging modality that uses radioactive substances (radiotracers) to measure changes in metabolic processes. Advances in scanner technology and data acquisition in the last decade have led to the development of more sophisticated PET devices with good spatial resolution (1–3 mm of full width at half maximum (FWHM)). However, there are involuntary motions produced by the patient inside the scanner that lead to image degradation and potentially to a misdiagnosis. The adverse effect of the motion in the reconstructed image increases as the spatial resolution of the current scanners continues improving. In order to correct this effect, motion correction techniques are becoming increasingly popular and further studied. This work presents a simulation study of an image motion correction using a frame-based algorithm. The method is able to cut the acquired data from the scanner in frames, taking into account the size of the object of study. This approach allows working with low statistical information without losing image quality. The frames are later registered using spatio-temporal registration developed in a multi-level way. To validate these results, several performance tests are applied to a set of simulated moving phantoms. The results obtained show that the method minimizes the intra-frame motion, improves the signal intensity over the background in comparison with other literature methods, produces excellent values of similarity with the ground-truth (static) image and is able to find a limit in the patient-injected dose when some prior knowledge of the lesion is present.

Funder

Spanish Government Grant

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference84 articles.

1. Taking the perfect nuclear image: Quality control, acquisition, and processing techniques for cardiac SPECT, PET, and hybrid imaging

2. Frequent Diagnostic Errors in Cardiac PET/CT Due to Misregistration of CT Attenuation and Emission PET Images: A Definitive Analysis of Causes, Consequences, and Corrections

3. Image derived input functions for dynamic High Resolution Research Tomograph PET brain studies

4. Head Movement in Normal Subjects During Simulated PET Brain Imaging with and without Head Restraint;Green;J. Nucl. Med.,1994

5. On the Use of Positioning Aids to Reduce Misregistration in the Head and Neck in Whole-Body PET/CT Studies;Beyer;J. Nucl. Med.,2005

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Motion in nuclear cardiology imaging: types, artifacts, detection and correction techniques;Physics in Medicine & Biology;2022-01-17

2. Influence of Speed Motion in Dedicated Open Geometry PET System;2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC);2021-10-16

3. Computer Vision for 3D Perception and Applications;Sensors;2021-06-08

4. Image Motion Correction of GATE Simulation in Dedicated PET Scanner with Open Geometry;Bioengineering and Biomedical Signal and Image Processing;2021