Near-Infrared Spectroscopy with Supervised Machine Learning as a Screening Tool for Neutropenia

Author:

Raposo-Neto José Joaquim12,Kowalski-Neto Eduardo1,Luiz Wilson Barros23,Fonseca Estherlita Almeida23,Cedro Anna Karla Costa Logrado23,Singh Maneesh N.45,Martin Francis L.46ORCID,Vassallo Paula Frizera7,Campos Luciene Cristina Gastalho123ORCID,Barauna Valerio Garrone8

Affiliation:

1. Department of Health Sciences, State University of Santa Cruz, Ilhéus 45662-900, Brazil

2. Laboratory of Applied Pathology and Genetics, State University of Santa Cruz, Ilhéus 45662-900, Brazil

3. Department of Biological Science, State University of Santa Cruz, Ilhéus 45662-900, Brazil

4. Biocel UK Ltd., Hull HU10 6TS, UK

5. Chesterfield Royal Hospital, Chesterfield S44 5BL, UK

6. Department of Cellular Pathology, Blackpool Teaching Hospitals NHS Foundation Trust, Whinney Heys Road, Blackpool FY3 8NR, UK

7. Clinical Hospital Universidade Federal de Minas Gerais, Belo Horizonte 31270-901, Brazil

8. Department of Physiological Science, Federal University of Espírito Santo, Vitória 29932-540, Brazil

Abstract

The use of non-invasive tools in conjunction with artificial intelligence (AI) to detect diseases has the potential to revolutionize healthcare. Near-infrared spectroscopy (NIR) is a technology that can be used to analyze biological samples in a non-invasive manner. This study evaluated the use of NIR spectroscopy in the fingertip to detect neutropenia in solid-tumor oncologic patients. A total of 75 patients were enrolled in the study. Fingertip NIR spectra and complete blood counts were collected from each patient. The NIR spectra were pre-processed using Savitzky–Golay smoothing and outlier detection. The pre-processed data were split into training/validation and test sets using the Kennard–Stone method. A toolbox of supervised machine learning classification algorithms was applied to the training/validation set using a stratified 5-fold cross-validation regimen. The algorithms included linear discriminant analysis (LDA), logistic regression (LR), random forest (RF), multilayer perceptron (MLP), and support vector machines (SVMs). The SVM model performed best in the validation step, with 85% sensitivity, 89% negative predictive value (NPV), and 64% accuracy. The SVM model showed 67% sensitivity, 82% NPV, and 57% accuracy on the test set. These results suggest that NIR spectroscopy in the fingertip, combined with machine learning methods, can be used to detect neutropenia in solid-tumor oncology patients in a non-invasive and timely manner. This approach could help reduce exposure to invasive tests and prevent neutropenic patients from inadvertently undergoing chemotherapy.

Funder

Universidade Estadual de Santa Cruz

FAPESB

FAPES

CNPq

NIHR Manchester Biomedical Research Centre

Publisher

MDPI AG

Subject

Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3