Preliminary Numerical Analysis of Mechanical Wave Propagation Due to Elastograph Measuring Head Application in Non-Invasive Liver Condition Assessment

Author:

Romanowska Katarzyna1,Pyka Dariusz2ORCID,Opieliński Krzysztof3ORCID,Krawiec Karina2ORCID,Śliwiński Robert4,Jamroziak Krzysztof2ORCID

Affiliation:

1. Provincial Specialist Hospital in Wroclaw, Research and Development Centre, Kaminskiego 73A Str., 51-124 Wroclaw, Poland

2. Department of Mechanics, Materials and Biomedical Engineering, Wroclaw University of Science and Technology, Smoluchowskiego 25 Str., 50-370 Wroclaw, Poland

3. Department of Acoustics, Multimedia and Signal Processing, Wroclaw University of Science and Technology, Janiszewskiego 7/9 Str., 50-370 Wroclaw, Poland

4. TIBA Ltd., Kruszwicka 51/10 Str., 53-652 Wroclaw, Poland

Abstract

The authors of this paper focused their attention on developing numerical models of mechanical wave propagation along human tissue as a result of the application of the measuring head of the FibroScan® elastograph. The FibroScan® diagnostic device is used for diagnostic testing of liver fibrosis and steatosis. This examination is carried out using an in vivo method by directly applying the surface of the ultrasonic measuring probe to the patient’s skin at the site of the liver. The authors’ idea is to use this apparatus for non-invasive testing on the liver used for transplantation. In order to do this, the measuring head cap should be modified so that its application to the liver does not result in damage as a result of mechanical wave excitation. The purpose of the manuscript was to build numerical models of the liver and the tissues surrounding the liver. Then, the corresponding numerical simulations were carried out, the results of which corresponded to the mechanical–acoustic properties of the physical models of the tissues. The obtained results were validated on a set of commercial calibrated phantoms. High agreement of the numerical models was obtained.

Funder

European Regional Development Fund

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Reference35 articles.

1. Elastografia Wątroby w Codziennej Praktyce Klinicznej/ Liver Elastography in Everyday Clinical Practice;Milkiewicz;Gastroenterol. Klin.,2017

2. FibroScan Evaluation of Liver Fibrosis in Liver Transplantation;Vallecillo;Transplant. Proc.,2009

3. Current Techniques and Future Trends in the Diagnosis of Hepatic Steatosis in Liver Donors: A Review;Rajamani;J. Liver Transplant.,2022

4. Stiffness and Impedance: The New Liver Biomarkers;Malik;Clin. Gastroenterol. Hepatol.,2007

5. Non-Invasive Evaluation of Liver Fibrosis Using Transient Elastography;Castera;J. Hepatol.,2008

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3