Correlation between Volumes Determined by Echocardiography and Cardiac MRI in Controls and Atrial Fibrillation Patients

Author:

Manole Simona,Budurea Claudia,Pop SorinORCID,Iliescu Alin M.,Ciortea Cristiana A.,Iancu Stefania D.,Popa Loredana,Coman Mihaela,Szabó László,Coman Vasile,Bálint ZoltánORCID

Abstract

Aims: We aimed to compare cardiac volumes measured with echocardiography (echo) and cardiac magnetic resonance imaging (MRI) in a mixed cohort of healthy controls (controls) and patients with atrial fibrillation (AF). Materials and methods: In total, 123 subjects were included in our study; 99 full datasets were analyzed. All the participants underwent clinical evaluation, EKG, echo, and cardiac MRI acquisition. Participants with full clinical data were grouped into 63 AF patients and 36 controls for calculation of left atrial volume (LA Vol) and 51 AF patients and 30 controls for calculation of left ventricular end-diastolic volume (LV EDV), end-systolic volume (ESV), and LV ejection fraction (LV EF). Results: No significant differences in LA Vol were observed (p > 0.05) when measured by either echo or MRI. However, echo provided significantly lower values for left ventricular volume (p < 0.0001). The echo LA Vol of all the subjects correlated well with that measured by MRI (Spearmen correlation coefficient r = 0.83, p < 0.0001). When comparing the two methods, significant positive correlations of EDV (all subjects: r = 0.55; Controls: r = 0.71; and AF patients: r = 0.51) and ESV (all subjects: r = 0.62; Controls: r = 0.47; and AF patients: r = 0.66) were found, with a negative bias for values determined using echo. For a subgroup of participants with ventricular volumes smaller than 49.50 mL, this bias was missing, thus in this case echocardiography could be used as an alternative for MRI. Conclusion: Good correlation and reduced bias were observed for LA Vol and EF determined by echo as compared to cardiac MRI in a mixed cohort of patients with AF and healthy volunteers. For the determination of volume values below 49.50 mL, an excellent correlation was observed between values obtained using echo and MRI, with comparatively reduced bias for the volumes determined by echo. Therefore, in certain cases, echocardiography could be used as a less expensive, less time-consuming, and contraindication free alternative to MRI for cardiac volume determination.

Publisher

MDPI AG

Subject

Paleontology,Space and Planetary Science,General Biochemistry, Genetics and Molecular Biology,Ecology, Evolution, Behavior and Systematics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3