Influence of Physical Activity and Cup Orientation on Metal Ion Release and Oxidative Stress in Metal-on-Metal and Ceramic-on-Metal Total Hip Arthroplasty

Author:

Gómez-Álvarez Jorge1,Miranda Ignacio23ORCID,Álvarez-Llanas Alejandro23,Lisón Juan F.45ORCID,Bosch-Morell Francisco4ORCID,Doménech Julio1ORCID

Affiliation:

1. Department of Orthopedic Surgery, Clínica Universidad de Navarra, 31008 Pamplona, Spain

2. Department of Orthopedic Surgery, Hospital Arnau de Vilanova, 46015 Valencia, Spain

3. Faculty of Health Sciences, Universidad Católica de Valencia, 46001 Valencia, Spain

4. Department of Biomedical Sciences, Faculty of Health Sciences, University CEU Cardenal Herrera, 46115 Alfara del Patriarca, Spain

5. CIBER de Fisiopatología de la Obesidad y Nutrición, Instituto de Salud Carlos III, 28029 Madrid, Spain

Abstract

Background: Metal-on-metal (M-M) total hip arthroplasty (THA) has shown adverse reactions to metal debris, abnormal soft-tissue reactions, and high blood metal ion levels. This study aims to: (1) assess whether the toxicity of high levels of ions is related to altered oxidative stress and (2) evaluate tribological factors related to increased blood levels of chromium (Cr) and cobalt (Co) ions. Methods: A cross-sectional analytical descriptive study was conducted on 75 patients. A total of 25 underwent M-M THA, 25 ceramic-on-metal (C-M) THA, and 25 were on the THA waiting list. Ion metallic levels in blood, oxidative stress, physical activity, and implant position were compared. Results: In the M-M group, Co and Cr levels were significantly higher than those found in the C-M group and the control group (p < 0.01). We found no differences in terms of oxidative stress between the groups. Also, we did not find a correlation between metal blood levels and oxidative stress indicators, the physical activity of the patients or the position of the implants between groups. Conclusions: The use of M-M bearing surfaces in THA raises the levels of metals in the blood without modifying oxidative stress regardless of the physical activity levels of the patients. Therefore, although patients with M-M bearings require close monitoring, it does not seem necessary to recommend the restriction of physical activity in patients with M-M or C-M arthroplasties.

Funder

University CEU-Cardenal Herrera

Publisher

MDPI AG

Subject

General Medicine