Occupational Exposure to Biological Agents in a Typical Restaurant Setting: Is a Photocatalytic Air Purifier Helpful?

Author:

Ratti Matteo1ORCID,Ceriotti Daniele1ORCID,Bibi Rabia1ORCID,Conti Andrea1ORCID,Panella Massimiliano1ORCID

Affiliation:

1. Department of Translational Medicine (DiMeT), Università del Piemonte Orientale, 28100 Novara, Italy

Abstract

According to many national legislations, biological agents represent an occupational hazard that must be managed in order to ensure safety at workplace. Bioaerosols have been associated to many pathological conditions but, despite many efforts, precise threshold limit values (TLV) are still undefined. We planned and conducted an environmental study concerning a typical restaurant that aimed to evaluate: (1) the occupational exposure to bacterial and fungal bioaerosol; (2) the efficacy of a photocatalytic air purifier device in mitigating such exposure. This observational study evaluated two dining rooms (Area 1 and Area 2) of a restaurant which can be considered typical during two consecutive weeks. Based on a national protocol, we monitored total bacterial and mycotic loads searching for two typologies of bacteria, psychrophilic bacteria (environmental contamination) along with mesophilic bacteria (human or animal origin source), and two types of fungi, mold and yeast. Baseline total bacterial load was 346.8 CFU/m3 for Area 1 and 412.9 CFU/m3 for Area 2. When the sanitizing device was operative, the total bacterial load decreased to 202.7 CFU/m3 (−41.50%—p value: <0.01) for Area 1 and to 342.2 CFU/m3 (−17.10%—p value: 0.06) for Area 2. Considering the fungal load, the mean baseline value was 189.7 CFU/m3 for Area 1 and 141.1 CFU/m3 for Area 2. When the device was kept on, the total fungal load was 108.0 CFU/m3 (−43.10%—p value: 0.055) for Area 1 and 205.0 CFU/m3 (+45.30%—p value: 0.268) for Area 2. Our findings supported the conclusion that, concerning the occupational risk derived from biological agents, a typical restaurant should be considered relatively safe. In order to mitigate or limit any possible increase of such risk, a photocatalytic device may be helpful, but not against the pollution caused by mold or yeasts. Our research also reaffirmed the need of further research assessing the kind of relationship between diseases and exposure levels, before considering the need of setting precise threshold limit values.

Publisher

MDPI AG

Subject

Public Health, Environmental and Occupational Health,Safety Research,Safety, Risk, Reliability and Quality

Reference58 articles.

1. Fungal bioaerosol as an occupational hazard in the podiatrist’s workplace;Collado;Int. J. Environ. Health Res.,2023

2. (2019). On the interpretation of bioaerosol exposure measurements and impacts on health. J. Air Waste Manag. Assoc., 69, 789–804.

3. Dental bioaerosol as an occupational hazard in a dentist’s workplace;Ann. Agric. Environ. Med. AAEM,2007

4. Occupational endotoxin exposure and health effects;Liebers;Arch. Toxicol.,2020

5. Cotton dust and endotoxin exposure-response relationships in cotton textile workers;Kennedy;Am. Rev. Respir. Dis.,1987

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3