Intranasal Lidocaine Administration via Mucosal Atomization Device: A Simple and Successful Treatment for Postdural Puncture Headache in Obstetric Patients

Author:

Siegler Benedikt Hermann1,dos Santos Pereira Rui Pedro1,Keßler Jens1,Wallwiener Stephanie2,Wallwiener Markus2,Larmann Jan1,Picardi Susanne1,Carr Richard3ORCID,Weigand Markus Alexander1,Oehler Beatrice1ORCID

Affiliation:

1. Department of Anesthesiology, Medical Faculty Heidelberg, Heidelberg University, Im Neuenheimer Feld 420, D-69120 Heidelberg, Germany

2. Department of General Gynecology and Obstetrics with Polyclinic, Women’s Hospital, Medical Faculty Heidelberg, Heidelberg University, Im Neuenheimer Feld 440, D-69120 Heidelberg, Germany

3. Department of Anesthesiology, Medical Faculty Heidelberg, Universitaetsmedizin Mannheim, Heidelberg University, Ludolf-Krehl-Str. 13-17, D-68167 Mannheim, Germany

Abstract

(1) Background: Postdural puncture headache (PDPH) remains a serious complication in obstetric patients. While the epidural blood patch represents the current gold standard in therapy, a growing number of alternative measures are thought to be beneficial for clinical management. The purpose of this study was to retrospectively analyze the efficacy of intranasal lidocaine administration to treat PDPH in obstetrics at our university hospital; (2) Methods: A retrospective analysis of the medical records of patients with PDPH has been performed focusing on the techniques of administration, dosing, treatment duration, impact on pain intensity as well as side effects of intranasal lidocaine; (3) Results: During the study period, 5610 obstetric patients received neuraxial anesthesia, of whom 43 (0.77%) developed PDPH. About one third of the patients with PDPH after spinal anesthesia (n = 8), epidural anesthesia (n = 5) or both (n = 2) were treated with intranasal lidocaine. Lidocaine was administered either via gauze compresses (GC, n = 4), a mucosal atomization device (MAD, n = 8) or with a second-line mucosal atomization device due to low gauze compress efficacy (n = 3). All patients treated with lidocaine refused the epidural blood patch. Nebulization of lidocaine resulted in a significant reduction in pain intensity after the first dose (p = 0.008). No relevant side effects developed except sporadic temporal pharyngeal numbness. The utilization of the mucosal atomization device averted the necessity for an epidural blood patch, whether employed as the primary or secondary approach; (4) Conclusions: Our data imply that the mucosal atomization device enhances the efficacy of intranasal lidocaine administration in obstetric patients suffering from PDPH.

Funder

German Research Foundation

Deutsche Forschungsgemeinschaft

Publisher

MDPI AG

Subject

General Biochemistry, Genetics and Molecular Biology,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3