Impact of Previous Continuous Positive Airway Pressure Use on Noninvasive Ventilation Adherence and Quality in Obesity Hypoventilation Syndrome: A Pragmatic Single-Center Cross-Sectional Study in Martinique

Author:

Agossou Moustapha1ORCID,Awanou Bérénice1,Inamo Jocelyn2ORCID,Rejaudry-Lacavalerie Mickael3,Arnal Jean-Michel4ORCID,Dramé Moustapha56ORCID

Affiliation:

1. Department of Respiratory Medicine, CHU of Martinique, 97261 Fort-de-France, France

2. Department of Cardiology, CHU of Martinique, 97261 Fort-de-France, France

3. Department of Neurophysiology, CHU of Martinique, 97261 Fort-de-France, France

4. Intensive Care Unit, Hôpital Sainte Musse, 83100 Toulon, France

5. Department of Clinical Research and Innovation, CHU of Martinique, 97261 Fort-de-France, France

6. EpiCliV Research Unit, Faculty of Medicine, University of the French West Indies, 97261 Fort-de-France, France

Abstract

There is a strong relationship between obstructive sleep apnea (OSA) and obesity hypoventilation syndrome (OHS). When OHS is combined with severe OSA, treatment consists of continuous positive airway pressure (CPAP), followed by noninvasive ventilation (NIV) in the case of CPAP failure. Currently, the impact of a previous use of CPAP on the quality of NIV is unknown. We conducted a cross-sectional study with OHS patients, to assess the quality of NIV according to previous CPAP use. We included 75 patients with OHS on NIV (65 women, 87%). Among these, 40 patients (53.3%) who had had prior CPAP (CPAP+ group) were compared to the remaining 35 patients (46.7%) (CPAP− group). Key characteristics were comparable between the CPAP+ and the CPAP− groups: age at diagnosis of OHS was 67 ± 3 vs. 66 ± 4 years (p = 0.8), age at inclusion was 73 ± 15 vs. 69 ± 15 years (p = 0.29), number of comorbidities was 3.7 ± 1.2 vs. 3.3 ± 1.5, the Charlson index was 5.1 ± 2 vs. 4.6 ± 1.8, and BMI was 41.6 ± 7.6 kg/m2 vs. 41.2 ± 8.2, respectively, all p > 0.05. Follow-up length was greater in CPAP+ vs. CPAP− patients (5.6 ± 4.2 vs. 2.9 ± 2.9 years, p = 0.001). The quality of NIV based on daily adherence, pressure support, apnea–hypopnea index (AHI) and leaks was similar in both groups. Reduced adherence (less than 4 h daily) was found in 10 CPAP+ patients (25%) versus 7 CPAP− patients (20%), p = 0.80. NIV efficacy was also similar. This study found no difference in the quality of NIV or in adherence between patients who had had prior CPAP and those who had not. Previous CPAP does not appear to improve the quality of NIV.

Publisher

MDPI AG

Subject

General Biochemistry, Genetics and Molecular Biology,Medicine (miscellaneous)

Reference22 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3