Ultrasound Strain Elastography Reliability in the Assessment of the Plantar Fascia and Its Relationship with the Plantar Thickness in Healthy Adults: An Intra and Interobserver Reliability Study in Novice Evaluators

Author:

Aguilar-Nuñez Daniel12ORCID,Cervera-Garvi Pablo1ORCID,Aguilar-Garcia Maria3ORCID,Cuevas-Cervera Maria23ORCID,Gonzalez-Muñoz Ana23,Navarro-Ledesma Santiago3ORCID

Affiliation:

1. Department of Nursing and Podiatry, Faculty of Health Sciences, University of Malaga, Arquitecto Francisco Penalosa 3, Ampliación de Campus de Teatinos, 29071 Malaga, Spain

2. Clinica Ana Gonzalez, Avenida Hernan Nuñez de Toledo 6, 29018 Malaga, Spain

3. Department of Physiotherapy, Faculty of Health Sciences, Campus of Melilla, University of Granada, Querol Street, 5, 52004 Melilla, Spain

Abstract

Purpose. This study was aimed at verifying both the intraobserver and interobserver reliability of measuring plantar fascia stiffness for a given image in healthy active adults. Methodology. This study is reported following the Guidelines of Reporting Reliability and Agreement Studies. A total of 20 plantar fascia from healthy volunteers were analyzed. The thickness of the plantar fascia was measured vertically from the anterior edge of the inferior calcaneal border to the inferior border of the plantar fascia and the ultrasound elastography measurement was taken at the calcaneal insertion of the plantar fascia with the region of interest one centimeter away from the insertion. Results. The ultrasound strain elastography measurements: the right intraobserver 1 showed an ICC value of 0.9 and the left intraobserver 1 showed an ICC value of 0.78, while the right intraobserver 2 showed an ICC value of 0.91 and the left intraobserver 2 showed an ICC value of 0.83. Interobserver measurements showed excellent reliability with a right ICC value of 0.8 and a left ICC value of 0.9 for the plantar fascia thickness measurements. Discussion. The results of this study showed a strong correlation between left and right plantar fascia thickness. The intraobserver reliability was excellent for both plantar fascia ultrasound strain elastography and thickness measurements, with interobserver measurements showing excellent reliability.

Publisher

MDPI AG

Subject

General Biochemistry, Genetics and Molecular Biology,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3