Abstract
We compared the effects of right ventricular (RVP; n = 26) and His bundle (HBP; n = 24) pacing in patients with atrioventricular conduction disorders and preserved LVEF. Postoperatively (1D), and after six months (6M), the patients underwent global longitudinal strain (GLS) and peak systolic dispersion (PSD) evaluation with 2D speckle-tracking echocardiography, assessment of left atrial volume index (LAVI) and QRS duration (QRSd), and sensing/pacing parameter testing. The RVP threshold was lower than the HBP threshold at 1D (0.65 ± 0.13 vs. 1.05 ± 0.20 V, p < 0.001), and then it remained stable, while the HBP threshold increased at 6M (1.05 ± 0.20 vs. 1.31 ± 0.30 V, p < 0.001). The RVP R-wave was higher than the HBP R-wave at 1D (11.52 ± 2.99 vs. 4.82 ± 1.41 mV, p < 0.001). The RVP R-wave also remained stable, while the HBP R-wave decreased at 6M (4.82 ± 1.41 vs. 4.50 ± 1.09 mV, p < 0.02). RVP QRSd was longer than HBP QRSd at 6M (145.0 ± 11.1 vs. 112.3 ± 9.3 ms, p < 0.001). The absolute value of RVP GLS decreased at 6M (16.32 ± 2.57 vs. 14.03 ± 3.78%, p < 0.001), and HBP GLS remained stable. Simultaneously, RVP PSD increased (72.53 ± 24.15 vs. 88.33 ± 30.51 ms, p < 0.001) and HBP PSD decreased (96.28 ± 33.99 vs. 84.95 ± 28.98 ms, p < 0.001) after 6 months. RVP LAVI increased (26.73 ± 5.7 vs. 28.40 ± 6.4 mL/m2, p < 0.05), while HBP LAVI decreased at 6M (30.03 ± 7.8 vs. 28.73 ± 8.7 mL/m2, p < 0.01). These results confirm that HBP does not disrupt ventricular synchrony and provides advantages over RVP.
Subject
Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health
Cited by
11 articles.
订阅此论文施引文献