Microparticle Hybrid Target Simulation for keV X-ray Sources

Author:

Behling Rolf1ORCID,Hulme Christopher2ORCID,Tolias Panagiotis3ORCID,Poludniowski Gavin4,Danielsson Mats1

Affiliation:

1. Particle-, Astrophysics and Medical Imaging Department, KTH Royal Institute of Technology, SE-100 44 Stockholm, Sweden

2. Department of Materials Science and Engineering, KTH Royal Institute of Technology, SE-100 44 Stockholm, Sweden

3. Department of Space and Plasma Physics, KTH Royal Institute of Technology, SE-100 44 Stockholm, Sweden

4. Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Framstegsgatan 21, 17176 Stockholm, Sweden

Abstract

The spatiotemporal resolution of diagnostic X-ray images obtained with rotating-anode X-ray tubes has remained limited as the development of rigid, high-performance target materials has slowed down. However, novel imaging techniques using finer detector pixels and orthovolt cancer therapy employing narrow X-ray focal spots demand improved output from brilliant keV X-ray sources. Since its advent in 1929, rotating-anode technology has become the greatest bottleneck to improvement. To overcome this limitation, the current authors have devised a novel X-ray generation technology based on tungsten microparticle targets. The current study investigated a hybrid solution of a stream of fast tungsten microparticles and a rotating anode to both harvest the benefits of the improved performance of the new solution and to reuse known technology. The rotating anode captures energy that may pass a partially opaque microparticle stream and thereby contributes to X-ray generation. With reference to fast-rotating anodes and a highly appreciated small focal spot of a standardized size of 0.3 for an 8° target angle (physical: 0.45 mm × 4.67 mm), we calculated a potential output gain of at least 85% for non-melting microparticles and of 124% if melting is envisioned. Microparticle charging can be remediated by electron backscattering and electron field emission. The adoption of such a solution enables substantially improved image resolution.

Publisher

MDPI AG

Reference27 articles.

1. Heat management of a compact x-ray source for microbeam radiotherapy and FLASH treatments;Winter;Med. Phys.,2022

2. Bouwers, A.P. (1933). X-Ray Research and Development. A Selection of the Publications of the Philips X-Ray Research Laboratory from 1923–1933, Philips.

3. Bouwers, A.P.E.N. (1937). X-Ray Tube Having a Rotary Anode. (2081789), U.S. Patent.

4. Dose reduction potential in diagnostic single energy CT through patient-specific prefilters and a wider range of tube voltages;Steidel;Med. Phys.,2022

5. To bin or not to bin? The effect of CT system limiting resolution on noise and detectability;Baek;Phys. Med. Biol.,2013

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3