Stepping Beyond Counts in Recovery of Total Hip Arthroplasty: A Prospective Study on Passively Collected Gait Metrics

Author:

Fary Camdon12,Cholewa Jason3,Abshagen Scott3,Van Andel Dave3ORCID,Ren Anna3,Anderson Mike B.3ORCID,Tripuraneni Krishna4

Affiliation:

1. Epworth Foundation, Richmond, VIC 3121, Australia

2. Department of Orthopaedics, Western Hospital, Melbourne, VIC 3011, Australia

3. Zimmer Biomet, Warsaw, IN 46580, USA

4. New Mexico Orthopaedic Associates, Albuquerque, NM 87110, USA

Abstract

Gait quality parameters have been used to measure recovery from total hip arthroplasty (THA) but are time-intensive and previously could only be performed in a lab. Smartphone sensor data and algorithmic advances presently allow for the passive collection of qualitative gait metrics. The purpose of this prospective study was to observe the recovery of physical function following THA by assessing passively collected pre- and post-operative gait quality metrics. This was a multicenter, prospective cohort study. From six weeks pre-operative through to a minimum 24 weeks post-operative, 612 patients used a digital care management application that collected gait metrics. Average weekly walking speed, step length, timing asymmetry, and double limb support percentage pre- and post-operative values were compared with a paired-sample t-test. Recovery was defined as the post-operative week when the respective gait metric was no longer statistically inferior to the pre-operative value. To control for multiple comparison error, significance was set at p < 0.002. Walking speeds and step length were lowest, and timing asymmetry and double support percentage were greatest at week two post-post-operative (p < 0.001). Walking speed (1.00 ± 0.14 m/s, p = 0.04), step length (0.58 ± 0.06 m/s, p = 0.02), asymmetry (14.5 ± 19.4%, p = 0.046), and double support percentage (31.6 ± 1.5%, p = 0.0089) recovered at 9, 8, 7, and 10 weeks post-operative, respectively. Walking speed, step length, asymmetry, and double support all recovered beyond pre-operative values at 13, 17, 10, and 18 weeks, respectively (p < 0.002). Functional recovery following THA can be measured via passively collected gait quality metrics using a digital care management platform. The data suggest that metrics of gait quality are most negatively affected two weeks post-operative; recovery to pre-operative levels occurs at approximately 10 weeks following primary THA, and follows a slower trajectory compared to previously reported step count recovery trajectories.

Funder

Zimmer Biomet

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3