Affiliation:
1. Department of Infrastructure and Water Management, Rzeszow University of Technology, Al. Powstańców Warszawy 6, 35-959 Rzeszów, Poland
Abstract
Significant amounts of waste heat are deposited in greywater, which can be utilized, among other things, for heating domestic hot water in residential buildings. The manuscript presents an economic analysis of a greywater heat recovery system using a vertical heat exchanger of the “tube-in-tube” type in a single-family building. The analysis is based on the results of experimental research on the energy efficiency of three domestic hot water preparation systems equipped with a vertical heat exchange unit. The analyzed systems had different concepts for the flow of preheated water and cold water. The research showed that the implementation of a vertical “tube-in-tube” heat exchanger can reduce the energy consumption for domestic hot water preparation by approximately 45.7% to 60.8%, depending on the system variant. Furthermore, it was determined that the energy savings associated with reducing domestic hot water consumption can cover the investment costs related to the purchase and system of the heat exchanger within a period of 2 to 5 years of system operation, depending on the design variant and the unit price of electricity.
Subject
Management, Monitoring, Policy and Law,Nature and Landscape Conservation
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献