Benefits of Best Practice Guidelines in Spine Fusion: Comparable Correction in AIS with Higher Density and Fewer Complications

Author:

Fernandes Pedro12ORCID,Flores Isabel3,Soares do Brito Joaquim12

Affiliation:

1. Centro Hospitalar Universitário Lisboa Norte, Orthopaedics Department, Avenida Professor Egas Moniz, 1649-035 Lisboa, Portugal

2. Clínica Universitária de Ortopedia, Faculdade de Medicina da Universidade de Lisboa, Avenida Professor Egas Moniz, 1649-035 Lisboa, Portugal

3. ISCTE Instituto Universitário de Lisboa, 1649-026, Lisboa, Portugal

Abstract

Background: There is significant variability in surgeons’ instrumentation patterns for adolescent idiopathic scoliosis surgery. Implant density and costs are difficult to correlate with deformity correction, safety, and quality of life measures. Materials and Methods: Two groups of postoperative adolescents were compared based on exposure to a best practice guidelines program (BPGP) introduced to decrease complications. Hybrid and stainless steel constructs were dropped, and posterior-based osteotomies, screws, and implant density were increased to 66.8 ± 12.03 vs. 57.5 ± 16.7% (p < 0.001). The evaluated outcomes were: initial and final correction, rate of correction loss, complications, OR returns, and SRS-22 scores (minimum two-year follow-up). Results: 34 patients were operated on before BPGP and 48 after. The samples were comparable, with the exceptions of a higher density and longer operative times after BPGP. Initial and final corrections before BPGP were 67.9° ± 22.9 and 64.6° ± 23.7; after BPGP, the corrections were 70.6° ± 17.4 and 66.5° ± 14.9 (sd). A regression analysis did not show a relation between the number of implants and postoperative correction (beta = −0.116, p = 0.307), final correction (beta = −0.065, p = 0.578), or loss of correction (beta= −0.137, p = 0.246). Considering screw constructs only (n = 63), a regression model controlled for flexibility continued to show a slight negative effect of density on initial correction (b = −0.274; p = 0.019). Only with major curve concavity was density relevant in initial correction (b = 0.293; p = 0.038), with significance at 95% not being achieved for final correction despite a similar beta (b = 0.263; p = 0.069). Complications and OR returns dropped from 25.6% to 4.2%. Despite this, no difference was found in SRS-22 (4.30 ± 0.432 vs. 4.42 ± 0.39; sd) or subdomain scores pre- and post-program. Findings: Although it appears counterintuitive that higher density, osteotomies, and operative time may lead to fewer complications, the study shows the value of best practice guidelines in spinal fusions. It also shows that a 66% implant density leads to better safety and efficacy, avoiding higher costs.

Publisher

MDPI AG

Subject

Health Information Management,Health Informatics,Health Policy,Leadership and Management

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3