In Vitro Investigation of the Fixation Performance of a Bioabsorbable Magnesium ACL Interference Screw Compared to a Conventional Interference Screw

Author:

Siroros Nad1ORCID,Merfort Ricarda1,Liu Yu1,Praster Maximilian1,Hildebrand Frank1,Michalik Roman1ORCID,Eschweiler Jörg1

Affiliation:

1. Department of Orthopaedics, Trauma, and Reconstructive Surgery, University Hospital RWTH Aachen, 52074 Aachen, Germany

Abstract

An anterior cruciate ligament (ACL) reconstruction is a common treatment for patients with ACL rupture that aims to regain pre-injury knee stability and kinematics. During the ACL reconstruction, one method to fix the graft is the use of an interference screw (IS). The IS should provide initial stability and secure the graft during the healing period. In recent years, magnesium has emerged as an alternative material to permanent metal and polymer ISs. In addition, differences in designs, such as the shape of the IS, can influence the fixation performance of the IS. Therefore, in this biomechanical experiment, two different screw designs with two ligament materials were compared in an insertion and a pull-out test at a rate of 1 mm/s. The screw designs were a conventional polymer screw and a magnesium screw. Porcine tendon and nylon rope were used as ligament materials. All tests were performed in polyurethane foam blocks with 15 PCF density (Synbone AG, Switzerland). As a result, both screw designs required an insertion torque of less than 3 Nm. There was a significant difference between the porcine and nylon rope in pull-out tests for each screw design. The magnesium screw had the highest pull-out force at 412.14 ± 50.00 N for porcine tendon and 707.38 ± 21.81 N for nylon rope. There were no significant differences in tunnel widening (narrow–wide ratio) between each ligament material. The magnesium screw showed the lowest narrow–wide tunnel ratio, implying a better ability to compress the graft to the tunnel. In conclusion, a more optimized magnesium IS design resulted in better graft fixation and an improved ACL reconstruction outcome.

Publisher

MDPI AG

Subject

Paleontology,Space and Planetary Science,General Biochemistry, Genetics and Molecular Biology,Ecology, Evolution, Behavior and Systematics

Reference28 articles.

1. Study of the Effect of Cyclic Stress on the Mechanical Properties of Braided Anterior Cruciate Ligament (ACL);Fathy;J. Text. Sci. Eng.,2016

2. Fixation of the graft in reconstruction of the anterior cruciate ligament;Harvey;J. Bone Jt. Surg. Br.,2005

3. The cruciate ligaments of the knee joint. Anatomical, functional and experimental analysis;Girgis;Clin. Orthop. Relat. Res.,1975

4. Muscle strength and hop performance criteria prior to return to sports after ACL reconstruction;Kaplan;Knee Surg. Sports Traumatol. Arthrosc.,2011

5. Biomechanical comparison of pure magnesium interference screw and polylactic acid polymer interference screw in anterior cruciate ligament reconstruction—A cadaveric experimental study;Song;J. Orthop. Translat.,2017

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3