Concurrent Validity of Depth-Sensor-Based Quantification of Compensatory Movements during the Swing Phase of Gait in Healthy Individuals

Author:

Kusuda Kento1,Matsubara Shigehito12,Noguchi Daisuke3,Kuwahara Moe3,Hamasaki Hiroomi3,Miwa Toshihiro3,Maeda Toru3,Nakanishi Toshihito4,Ninomiya Shogo5,Honda Keita12ORCID

Affiliation:

1. Graduate School of Health Sciences, Kumamoto Health Science University, 325 Izumi-machi, Kita-ku, Kumamoto 861-5598, Japan

2. Department of Rehabilitation, Kumamoto Health Science University, 325 Izumi-machi, Kita-ku, Kumamoto 861-5598, Japan

3. Department of Physical Therapy, Kumamoto Kinoh Hospital, 6-8-1 Yamamuro, Kita-ku, Kumamoto 860-8518, Japan

4. Department of Rehabilitation, Kumamoto Kinoh Hospital, 6-8-1 Yamamuro, Kita-ku, Kumamoto 860-8518, Japan

5. Department of Physical Therapy, School of Health Science, Tokyo International University, 1-13-1 Matobakita, Kawagoe-shi, Saitama 350-1197, Japan

Abstract

The advancement in depth-sensor technology increased the potential for the clinical use of markerless three-dimensional motion analysis (3DMA); however, the accurate quantification of depth-sensor-based 3DMA on gait characteristics deviating from normal patterns is unclear. This study investigated the concurrent validity of the measurements of compensatory movements measured by depth-sensor-based 3DMA compared to those measured by marker-based 3DMA. We induced swing-phase compensatory movements due to insufficient toe clearance by restricting unilateral ankle and knee joint movements in healthy individuals. Thirty-two healthy young adults (nineteen males, aged 20.4 ± 2.0 years, height 164.4 ± 9.8 cm, weight 60.0 ± 9.3 kg [average ± standard deviation]) walked the 6 m walkway in slow speed, very slow speed, and knee–ankle–foot orthosis (KAFO; participants wore KAFOs on the right leg) conditions. Gait kinematics were measured with marker-based and depth-sensor-based 3DMA systems. The intraclass correlation coefficient (ICC3,1) was used to measure the relative agreement between depth-sensor-based and marker-based 3DMA and demonstrated good or moderate validity for swing-phase compensatory movement measurement. Additionally, the ICC2,1 measured absolute agreement between the systems and showed lower validity than the ICC3,1. The measurement errors for contralateral vaulting, trunk lateral flexion, hip hiking, swing-side hip abduction, and circumduction between instruments were 0.01 m, 1.30°, 1.99°, 2.37°, and 1.53°, respectively. Depth-sensor-based 3DMA is useful for determining swing-phase compensatory movements, although the possibility of missing a slight measurement error of 1–2° must be considered.

Funder

JSPS KAKENHI

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3