First Italian Experience with the Oxinium Metal-Backed Fixed-Bearing Medial Journey II Unicompartmental Knee System: Promising Short-Term Outcomes of 145 Cases

Author:

D’Amario Federico1,De Berardinis Luca2ORCID,Zanon Giacomo1,Qordja Fjorela2,Vitale Umberto3,Gigante Antonio Pompilio2

Affiliation:

1. Orthopedic Unit, Humanitas San Pio X, Via Francesco Nava, 31, 20159 Milano, Italy

2. Clinical Orthopedics, Department of Clinical and Molecular Sciences, School of Medicine, Università Politecnica delle Marche, Via Tronto, 10/a, 60126 Ancona, Italy

3. IRCCS Humanitas Research Hospital, Via Manzoni, 56, Rozzano, 20089 Milano, Italy

Abstract

(1) Background: Unicompartmental knee arthroplasty (UKA) provides a viable alternative to total knee arthroplasty (TKA) in patients with isolated medial osteoarthritis (OA). From 2007 to 2021, 23% of all primary knee arthroplasties in Italy were UKAs. We retrospectively evaluated clinical outcomes and satisfaction in patients implanted with a new oxinium metal-backed fixed-bearing medial unicompartmental prosthesis at a 24-month follow-up. (2) Methods: From December 2020 to December 2021, 145 patients were treated by a single surgeon at a single institution using the hypoallergenic Journey II prosthesis. Clinical outcome measures included the Knee Society Knee Score (KSKS), Knee Society Function Score (KSFS), Oxford Knee Society (OKS) score, University of California Los Angeles Activity Score (UCLA), the Physical Component Summary (PCS), and the Mental Component Summary (MCS), and were calculated preoperatively and at 12 and 24 months. The Forgotten Joint Score-12 (FJS-12) was calculated at 12 and 24 months. Patient satisfaction was collected at 24 months. The scores were compared using the Friedman test. (3) Results: All clinical scores improved significantly from baseline to 24 months (p < 0.0001), except for the FJS-12, which from 12 to 24 months did not improve significantly (p = 0.041). Patient satisfaction was 9.32 ± 0.74 out of 10. No patient experienced complications or required revision surgery. (4) Conclusions: The Journey II unicompartmental prosthesis is a valuable treatment option for end-stage medial OA, improving knee function, providing pain relief, and ensuring high patient satisfaction at 24 months.

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3