Affiliation:
1. ISISE, ARISE, Department of Civil Engineering, University of Coimbra, 3030-788 Coimbra, Portugal
2. Department of Civil Engineering and Management, Technical University of Cluj-Napoca, 400027 Cluj-Napoca, Romania
Abstract
The accurate evaluation of the thermal performance of building envelope components (e.g., facade walls) is crucial for the reliable evaluation of their energy efficiency. There are several methods available to quantify their thermal resistance, such as analytical formulations (e.g., ISO 6946 simplified calculation method), numerical simulations (e.g., using finite element method), experimental measurements under lab-controlled conditions or in situ. Regarding measurements, when using the heat flow meter (HFM) method, very often, the measured value is based on surface conditions (e.g., temperature and heat flux), achieving in this way the so-called surface-to-surface or conductive thermal resistance (Rcond). When the building components are made of homogeneous layers, their Rcond values are constant, regardless of their internal and external surface boundary conditions. However, whenever this element is composed of inhomogeneous layers, such as in lightweight steel-framed (LSF) walls, their Rcond values are no longer constant, depending on their thermal surface resistance. In the literature, such systematic research into how these Rcond values vary is not available. In this study, the values of four LSF walls were computed, with different levels of thermal conductivity inhomogeneity, making use of four finite elements’ numerical simulation tools. Six external thermal surface resistances (Rse) were modelled, ranging from 0.00 up to 0.20 m2·K/W. The average temperature of the partition LSF walls is 15 °C, while for the facade LSF walls it is 10 °C. It was found that the accuracy values of all evaluated numerical software are very high and similar, the Rcond values being nearly constant for walls with homogeneous layers, as expected. However, the variation in the Rcond value depends on the level of inhomogeneity in the LSF wall layers, increasing up to 8%, i.e., +0.123 m2·K/W, for the evaluated Rse values.
Funder
FEDER funds from the Competitivity Factors Operational Programme—COMPETE
FCT—Foundation for Science and Technology
Ministry of Research, Innovation and Digitization, CCCDI—UEFISCDI
Reference50 articles.
1. (2002). European Parliament Directive 2002/91/EC of the European Parliament and of the Council of 16 December 2002 on the Energy performance of Buildings. Off. J. Eur. Commun., L1/65–L1/71.
2. European Parliament (2024). Energy Performance of Buildings (Recast), European Parliament Legislative Resolution of 12 March 2024 on the Proposal for a Directive of the European Parliament and of the Council on the Energy Performance of Buildings (Recast), COM(2021)0802–C9-0469/2021–2021/0426(COD).
3. (John) Advances in Building Simulation and Computational Techniques: A Review between 1987 and 2014;Wang;Energy Build.,2016
4. Building Energy Model Calibration: A Review of the State of the Art in Approaches, Methods, and Tools;Scarpa;J. Build. Eng.,2024
5. Contrasting the Capabilities of Building Energy Performance Simulation Programs;Crawley;Build. Environ.,2008