Analysis of Early-Retrieved Dual-Mobility Polyethylene Liners for Total Hip Replacement

Author:

Smeeton Mackenzie1ORCID,Isaac Graham1,Wilcox Ruth1,Anderson James2,Board Tim3ORCID,Van Citters Douglas W.4,Williams Sophie1ORCID

Affiliation:

1. Institute of Medical and Biological Engineering, University of Leeds, Leeds LS2 9JT, UK

2. DePuy Synthes Joint Reconstruction, Leeds LS11 8DT, UK

3. Wrightington, Wigan and Leigh NHS Foundation Trust, Wigan WN6 9EP, UK

4. Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA

Abstract

Despite their emerging use, the in vivo behaviour of dual-mobility (DM) total hip replacements (THRs) is not well understood. Therefore, the purpose of this study was to assess the articulating surfaces of 20 early-retrieved DM polyethylene liners (mean length of implantation 20.0 ± 18.8 months) for damage to improve the current understanding of their in vivo functional mechanisms. The internal and external surfaces of each liner were visually and geometrically assessed, and the material composition of embedded debris particles were further characterized. Scratching and pitting were the most common modes of damage identified on either surface, and a high incidence of burnishing (50%) and embedded debris (65%) were observed on the internal and external surfaces, respectively. Embedded debris particles were commonly titanium- or iron-based, although other materials such as cobalt-chrome and tantalum were also identified. The geometric assessment demonstrated highly variable damage patterns across the liners, with the internal surfaces commonly presenting with crescent-shaped, circumferential, or circular regions of penetration whilst the external surfaces commonly presented with regions of deep pitting or gouging. This study demonstrates that DM-THRs primarily articulate at the head/liner junction, and that polyethylene liners are capable of rotating about the femoral neck axis, although the extent of this may be limited in some cases. Additionally, this study suggests that intra-prosthetic dislocation and edge loading may remain pertinent failure mechanisms of DM implants despite the advent of highly crosslinked polyethylene and design features, thus highlighting the need for enhanced monitoring of these devices.

Funder

Engineering and Physical Sciences Research Council

DePuy Synthes

National Institute for Health and Care Research (NIHR), Leeds Biomedical Research Centre

Publisher

MDPI AG

Reference32 articles.

1. Treatment patterns and clinical and economic burden of hip dislocation following primary total hip arthroplasty in England;Galvain;Bone Jt. J.,2022

2. National Joint Registry (2024, February 13). 20th Annual Report 2023. Available online: www.njrcentre.org.uk.

3. American Joint Replacement Registry (2023). The Tenth Annual Report of the AJRR on Hip and Knee Arthroplasty, American Academy of Orthopaedic Surgeons.

4. Wear of dual-mobility cups: A review article;Laura;Int. Orthop.,2017

5. Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation;Adam;Orthop. Traumatol. Surg. Res.,2012