Influence of Implant–Abutment Connection Biomechanics on Biological Response: A Literature Review on Interfaces between Implants and Abutments of Titanium and Zirconia

Author:

Choi Sunyoung1,Kang Young Suk2ORCID,Yeo In-Sung Luke3ORCID

Affiliation:

1. Department of Prosthodontics, One-Stop Specialty Center, Seoul National University Dental Hospital, Seoul 03080, Republic of Korea

2. 618th Medical Company (Dental Area Support)/Dental Health Activity-Korea, Camp Humphreys, APO, AP 96297, USA

3. Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul 03080, Republic of Korea

Abstract

The interface between a dental implant and an abutment is stabilized by two mechanical characteristics: a preload of an abutment screw and the friction between the contact surfaces of the implant and the abutment. These mechanical properties are quantitatively analyzed by using physical and mechanical formulas. The important thing is that such mechanical properties cause various biological phenomena when medical devices are inserted into human bodies. Some mechanical complications in dental implant prostheses are closely associated with biological complications. This literature review explores the mechanical complications of the implant–abutment connection and their biological effects in a titanium dental implant system, which is the system most widely used in dental clinics. Understanding the biomechanics of the implant–abutment connection helps to predict the merits and limits of zirconia dental implants, which have been recently introduced and clinically applied.

Funder

National Research Foundation of Korea

Publisher

MDPI AG

Subject

Rehabilitation,Materials Science (miscellaneous),Biomedical Engineering,Oral Surgery

Reference98 articles.

1. Do zirconia dental implants present better clinical results than titanium dental implants? A systematic review and meta-analysis;Sales;J. Stomatol. Oral Maxillofac. Surg.,2023

2. Implant survival and complications. The Third EAO consensus conference 2012;Albrektsson;Clin. Oral Implant. Res.,2012

3. Is Zirconia a Viable Alternative to Titanium for Dental Implantology?;Vaghela;Eur. J. Prosthodont. Restor. Dent.,2022

4. Clinical complications of osseointegrated implants;Goodacre;J. Prosthet. Dent.,1999

5. Three interfaces of the dental implant system and their clinical effects on hard and soft tissues;Kim;Mater. Horiz.,2022

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3