Coronal Repercussions of the Maxillary Central Incisor Torque in the First Set of Aligners: A Retrospective Study

Author:

Oliveira Ana Catarina1ORCID,Rocha Ana Sofia1,Leitão Rita1ORCID,Maia Manuela2,Pinho Teresa13ORCID

Affiliation:

1. UNIPRO—Oral Pathology and Rehabilitation Research Unit, University Institute of Health Science (IUCS), CESPU, 4585-116 Gandra, Portugal

2. IPMAIA—Instituto Politécnico da Maia, Avenida Carlos de Oliveira Campos, Castêlo da Maia, 4475-690 Maia, Portugal

3. IBMC—Molecular and Cellular Biology Institute, i3S—Health Innovation and Research Institute, University of Porto, 4200-135 Porto, Portugal

Abstract

Coronal torque is one of the key factors in orthodontic treatment. An adequate torque value has an impact on aesthetics and soft tissue profile. The aim of this quantitative, comparative and observational longitudinal cohort study was to analyze the efficacy of the maxillary central incisor coronal torque in the Invisalign® system and evaluate the relation between coronal torque movement and patient’s facial biotype. In total, 27 patients were selected. The planned movements (TP) were obtained from the Invisalign Doctor Site® using mathematical formulas that consider the T0 measurements. Pre-treatment (T0) and after full use of the first set of aligners (T1) scanners were evaluated using Geomagic® Control X TM by superimposing T0 and T1 models using a transverse plane and the long axis of the tooth crown. IBM® SPSS® software was used for statistical purposes. We found statistically significant differences between T0 and T1 in pro-inclination and retro-inclination, as well as between achieved and planned values in pro-inclination (p = 0.011). We verified that hyperdivergent clinical cases presented higher mean values of coronal torque, and hypodivergent cases presented lower values. In pro-inclination, the differences between the planned and achieved values were greater in hypodivergent cases and smaller in hyperdivergent cases. In retro-inclination, the differences between the planned and achieved values were greater in normodivergent cases and smaller in hypodivergent cases. This study highlights that inefficacy is more accentuated in pro-inclination. Aligners are an effective tool for producing coronal repercussions of torque movement, being more effective in retro-inclination.

Funder

Cooperativa de Ensino Superior Politécnico e Universitário

Publisher

MDPI AG

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3