Are Absorbable Plates More Resistant to Infection Than Titanium Implants? An Experimental Pre-Clinical Trial in Rabbits

Author:

Kitridis Dimitrios1ORCID,Savvidis Panagiotis1,Cheva Angeliki2,Papalois Apostolos3,Givissis Panagiotis1ORCID,Chalidis Byron1ORCID

Affiliation:

1. 1st Orthopaedic Department, School of Medicine, Faculty of Health Science, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece

2. Department of Pathology, School of Medicine, Faculty of Health Science, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece

3. Experimental Research Center ELPEN, 19009 Athens, Greece

Abstract

Background: Infection of orthopaedic implants after internal fixation of bone fractures remains a major complication with occasionally devastating consequences. Recent studies have reported that the use of absorbable materials, instead of metallic ones, may lead to a lower incidence of postoperative infection. In this experimental pre-clinical animal study, we compared the infection rate between absorbable implants consisting of copolymers composed from trimethylene carbonate, L-polylactic acid, and D, L-polylactic acid monomers, and titanium implants after the inoculation of a pathogenic microorganism. Material and Methods: We used an experimental implant-related infection model in rabbits. Sixty animals were randomly and equally divided into two groups. In all animals, the right femur was exposed via a lateral approach and a 2.5 mm two-hole titanium plate with screws (Group A), or a two-hole absorbable plate and screws (Group B), were applied in the femoral shaft. Afterwards, the implant surface was inoculated with Pseudomonas Aeruginosa at a concentration of 2 × 108 CFU/mL. The primary outcome was the comparison of the incidence of developed infection between the two groups. The wound condition was monitored on a daily basis and radiographies were obtained at 12 weeks postoperatively. Infection-related laboratory markers (white blood cell count, erythrocyte sedimentation rate, and C-reactive protein values) were assessed at 3, 6, and 16 weeks postoperatively. Histologic analysis and cultures of tissue samples were also performed to evaluate the presence of infection. Results: Clinical and laboratory signs of infection were evident in 11 rabbits in Group A (36.7%), and 4 in Group B (13.3%). The difference between the groups was statistically significant (p = 0.04). Five animals in Group B (16.7%) had clinical and histologic signs of a foreign-body reaction with significantly elevated CRP and ESR values but no simultaneous presence of infection was identified (p = 0.04). Bone remodelling with thickening of the periosteum and surrounding sclerosis was demonstrated radiologically in animals developing infection or foreign-body reactions. Conclusions: Absorbable plates and screws show lower susceptibility to infection compared to titanium ones. However, their application is associated with foreign-body reaction and the potential need for a second surgical intervention.

Funder

Experimental Research Centre ELPEN

Publisher

MDPI AG

Subject

Biomedical Engineering,Biomaterials

Reference51 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3