Tissue Ablation Using Irreversible Electrolytic Electroporation with Reduced Voltage

Author:

Kim Ki-Han1,An Jinsu1,Park Young-Jin2ORCID,Park Jung-Hoon3ORCID,Kim Hong Bae4ORCID,Yi Jeong-Han1,Kim Hyung-Sik5ORCID

Affiliation:

1. Department of Biomedical Engineering, School of ICT Convergence Engineering, College of Science & Technology, Konkuk University, Chungju-si 27478, Republic of Korea

2. Department of Medicinal Biosciences, Research Institute for Biomedical & Health Science, College of Biomedical and Health Science, Konkuk University, Chungju-si 27478, Republic of Korea

3. Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, Olympic-ro, Seoul 05505, Republic of Korea

4. The Standard Co., Ltd., Gunpo-si 15880, Republic of Korea

5. Department of Mechatronics Engineering, School of ICT Convergence Engineering, College of Science & Technology, Konkuk University, Chungju-si 27478, Republic of Korea

Abstract

Thermal tissue ablation may damage surrounding healthy tissue and cause pain. In this study, tissue ablation with the sequential application of electrical energy-inducing irreversible electroporation (IRE) and electrolysis (EL) (IRE + EL = IREEL) was investigated. An IREEL device was designed to control five output pulse parameters: voltage level (VL), pulse width (PW), pulse interval (PI), pulse number (PN), and pulse tail time (PTT). IREEL experiments were conducted on vegetable tissue. The results indicated that by increasing the VL and PTT, the ablation area increased, whereas the impedance was reduced significantly. Almost no ablation area was observed when only EL or IRE at 500 V and 1000 V, respectively, were applied. The ablation area observed with IRE alone at 1500 V was defined as 100%. In the case of IREEL at 500 V and 1000 V, ablation was induced even with the use of micro-second level PTT, and ablation areas of 91% and 186% were achieved, respectively. For IREEL at a voltage of 1500 V, the ablation area expanded to 209% and the maximum temperature was 48.7 °C, whereas the temperature did not exceed 30 °C under other conditions. A change in pH was also observed in an agar-gel phantom experiment which was conducted to examine and confirm whether IREEL induced electrolysis. IREEL was able induce ablation at low voltages owing to the synergistic effect of applying IRE and EL sequentially. Moreover, the ablation areas at high voltages could be increased compared to the areas observed when IRE and EL were applied independently.

Funder

Konkuk University

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Computer Networks and Communications,Hardware and Architecture,Signal Processing,Control and Systems Engineering

Reference47 articles.

1. Optical signatures of radiofrequency ablation in biological tissues;Lanka;Sci. Rep.,2021

2. A review of high-intensity focused ultrasound as a novel and non-invasive interventional radiology technique;Yao;J. Interv. Med.,2022

3. The use of laser interstitial thermal therapy in the treatment of brain metastases: A literature review;Bastos;Int. J. Hyperth.,2022

4. Recent progress in cryoablation cancer therapy and nanoparticles mediated cryoablation;Kwak;Theranostics,2022

5. Automatic radiofrequency ablation planning for liver tumors with multiple constraints based on set covering;Liang;IEEE Trans. Med. Imaging,2020

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3