Abstract
Type 1 diabetes is a disease affecting beta cells of the pancreas and it’s responsible for a decreased insulin secretion, leading to an increased blood glucose level. The traditional method for glucose treatment is based on finger-stick measurement of the blood glucose concentration and consequent manual insulin injection. Nowadays insulin pumps and continuous glucose monitoring systems are replacing them, being simpler and automatized. This paper focuses on analyzing and improving the knowledge about which Machine Learning algorithms can work best with glycaemic data and tries to find out the relation between insulin pump settings and glycaemic control. The dataset is composed of 90 days of recordings taken from 16 children and adolescents. Three Machine Learning approaches, two for classification, Logistic Regression (LR) and Random Forest (RL), and one for regression, Multivariate Linear Regression (MLR), have been used for the purpose. Specifically, the pump settings analysis was performed based on the Time In Range (TIR) computation and comparison consequent to pump setting changes. RF and MLR have shown the best results, while, for the settings’ analysis, the data show a discrete correlation between changes and TIRs. This study provides an interesting closer look at the data recorded by the insulin pump and a suitable starting point for a thorough and complete analysis of them.
Subject
Electrical and Electronic Engineering,Computer Networks and Communications,Hardware and Architecture,Signal Processing,Control and Systems Engineering
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献