Evaluation of Extra-Prostatic Extension on Deep Learning-Reconstructed High-Resolution Thin-Slice T2-Weighted Images in Patients with Prostate Cancer

Author:

Kim Mingyu1,Kim Seung Ho1ORCID,Hong Sujin1,Kim Yeon Jung1,Kim Hye Ri1,Kim Joo Yeon2

Affiliation:

1. Department of Radiology, Haeundae Paik Hospital, Inje University College of Medicine, Busan 48108, Republic of Korea

2. Department of Pathology, Haeundae Paik Hospital, Inje University College of Medicine, Busan 48108, Republic of Korea

Abstract

The aim of this study was to compare diagnostic performance for extra-prostatic extension (EPE) and image quality among three image datasets: conventional T2-weighted images (T2WIconv, slice thickness, 3 mm) and high-resolution thin-slice T2WI (T2WIHR, 2 mm), with and without deep learning reconstruction (DLR) in patients with prostatic cancer (PCa). A total of 88 consecutive patients (28 EPE-positive and 60 negative) diagnosed with PCa via radical prostatectomy who had undergone 3T-MRI were included. Two independent reviewers performed a crossover review in three sessions, in which each reviewer recorded five-point confidence scores for the presence of EPE and image quality using a five-point Likert scale. Pathologic topographic maps served as the reference standard. For both reviewers, T2WIconv showed better diagnostic performance than T2WIHR with and without DLR (AUCs, in order, for reviewer 1, 0.883, 0.806, and 0.772, p = 0.0006; for reviewer 2, 0.803, 0.762, and 0.745, p = 0.022). The image quality was also the best in T2WIconv, followed by T2WIHR with DLR and T2WIHR without DLR for both reviewers (median, in order, 3, 4, and 5, p < 0.0001). In conclusion, T2WIconv was optimal in regard to image quality and diagnostic performance for the evaluation of EPE in patients with PCa.

Publisher

MDPI AG

Reference31 articles.

1. Prostate Imaging Reporting and Data System Version 2.1: 2019 Update of Prostate Imaging Reporting and Data System Version 2;Turkbey;Eur. Urol.,2019

2. Imaging Facilities’ Adherence to PI-RADS v2 Minimum Technical Standards for the Performance of Prostate MRI;Esses;Acad. Radiol.,2018

3. PI-RADS Prostate Imaging—Reporting and Data System: 2015, Version 2;Weinreb;Eur. Urol.,2016

4. Optimising prostate mpMRI: Prepare for success;Caglic;Clin. Radiol.,2019

5. Optimization of prostate MRI acquisition and post-processing protocol: A pictorial review with access to acquisition protocols;Jambor;Acta Radiol. Open,2017

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3