A Feasibility Study of Functional Lung Volume Preservation during Stereotactic Body Radiotherapy Guided by Gallium-68 Perfusion PET/CT

Author:

Lucia François12ORCID,Hamya Mohamed1,Pinot Fanny3,Goasduff Gaëlle1,Blanc-Béguin Frédérique34ORCID,Bourhis David34,Pradier Olivier12,Lucia Anne-Sophie1,Hennebicq Simon34,Mauguen Maëlle1,Floch Romain3,Schick Ulrike12,Bourbonne Vincent12ORCID,Salaün Pierre-Yves34,Le Roux Pierre-Yves34ORCID

Affiliation:

1. Radiation Oncology Department, University Hospital, 29200 Brest, France

2. LaTIM, INSERM, UMR 1101, University of Brest, 29200 Brest, France

3. Service de Médecine Nucléaire, CHRU de Brest, 29200 Brest, France

4. GETBO, INSERM, UMR1304, Université de Bretagne Occidentale, 29200 Brest, France

Abstract

The aim of this study was to assess the feasibility of sparing functional lung areas by integration of pulmonary functional mapping guided by 68Ga-perfusion PET/CT imaging in lung SBRT planification. Sixty patients that planned to receive SBRT for primary or secondary lung tumors were prospectively enrolled. Lung functional volumes were defined as the minimal volume containing 50% (FV50%), 70% (FV70%) and 90% (FV90%) of the total activity within the anatomical volume. All patients had a treatment planning carried out in 2 stages: an anatomical planning blinded to the PET results and then a functional planning respecting the standard constraints but also incorporating “lung functional volume” constraints. The mean lung dose (MLD) in functional volumes and the percentage of lung volumes receiving xGy (VxGy) within the lung functional volumes using both plans were calculated and compared. SBRT planning optimized to spare lung functional regions led to a significant reduction (p < 0.0001) of the MLD and V5 to V20 Gy in all functional volumes. Median relative difference of the MLD in the FV50%, FV70% and FV90% was −8.0% (−43.0 to 1.2%), −7.1% (−34.3 to 1.2%) and −5.7% (−22.3 to 4.4%), respectively. Median relative differences for VxGy ranged from −12.5% to −9.2% in the FV50%, −11.3% to −7.2% in the FV70% and −8.0% to −5.3% in the FV90%. This study shows the feasibility of significantly decreasing the doses delivered to the lung functional volumes using 68Ga-perfusion PET/CT while still respecting target volume coverage and doses to other organs at risk.

Funder

Ligue contre le cancer

Publisher

MDPI AG

Subject

Cancer Research,Oncology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3