Integration of Riboflavin-Modified Carbon Fiber Mesh Electrode Systems in a 3D-Printed Catheter Hub

Author:

Casimero Charnete1ORCID,Smith Robert B.2ORCID,Davis James1

Affiliation:

1. School of Engineering, Ulster University, Belfast BT15 1ED, UK

2. Institute for Materials and Investigative Sciences, University of Central Lancashire, Preston PR1 2HE, UK

Abstract

Background: Catheter line infection is a common complication within clinical environments, and there is a pressing need for technological options to aid in reducing the possibility of sepsis. The early identification of contamination could be pivotal in reducing cases and improving outcomes. Method: A sensing rationale based on a riboflavin-modified electrode system integrated within a modified 3D-printed catheter needle-free connector is proposed, which can monitor changes in pH brought about by bacterial contamination. Results: Riboflavin, vitamin B2, is a biocompatible chemical that possesses a redox-active flavin core that is pH dependent. The oxidation peak potential of the adsorbed riboflavin responds linearly to changes in pH with a near-Nernstian behavior of 63 mV/pH unit and is capable of accurately monitoring the pH of an authentic IV infusate. Conclusions: The proof of principle is demonstrated with an electrode-printed hub design offering a valuable foundation from which to explore bacterial interactions within the catheter lumen with the potential of providing an early warning of contamination.

Funder

Department for the Economy (DfE), Northern Ireland

Kimal PLC

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Mechanical Engineering,Control and Systems Engineering

Reference50 articles.

1. The Joint Commission (2012). Preventing Central Line–Associated Bloodstream Infections: A Global Challenge, a Global Perspective, Joint Commission Resources. Available online: https://www.jointcommission.org/-/media/tjc/documents/resources/hai/clabsi_monographpdf.pdf.

2. Increased Clinical and Economic Burden Associated With Peripheral Intravenous Catheter–Related Complications: Analysis of a US Hospital Discharge Database;Lim;INQUIRY J. Health Care Organ. Provis. Financ.,2019

3. Infection risks associated with peripheral vascular catheters;Zhang;J. Infect. Prev.,2016

4. Catheter-related bloodstream infections;Gahlot;Int. J. Crit. Illn. Inj. Sci.,2014

5. Systematic review of antimicrobial lock therapy for prevention of central-line-associated bloodstream infections in adult and pediatric cancer patients;Norris;Int. J. Antimicrob. Agents,2017