Comparison of the Feasibility and Diagnostic Performance of ACR CEUS LI‐RADS and a Modified CEUS LI‐RADS for HCC in Examinations Using Sonazoid

Author:

Liao Wei1,Que Qiao1,Wen Rong1,Lin Peng1,Chen Yuji1,Pang Jinshu1,Guo Danxia1,Wen Dongyue1,Yang Hong12ORCID,He Yun12ORCID

Affiliation:

1. Department of Medical Ultrasound The First Affiliated Hospital of Guangxi Medical University Nanning China

2. Guangxi Zhuang Autonomous Region Engineering Research Center for Artificial Intelligence Analysis of Multimodal Tumor Images Nanning China

Abstract

ObjectivesThe present study aimed to determine the feasibility of the American College of Radiology's (ACR) contrast‐enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI‐RADS) (version 2017) in examinations using Sonazoid and compare its diagnostic performance with that of modified LI‐RADS in patients at high risk of hepatocellular carcinoma (HCC).MethodsThis retrospective study's sample population consisted of 137 participants with a total of 140 nodules who underwent CEUS with Sonazoid and pathological confirmation via surgery or biopsy from January 2020 to February 2022. The lesions were evaluated and classified based on the reference standards (ie, ACR CEUS LI‐RADS and modified LI‐RADS). The overall diagnostic capabilities of the two systems were evaluated in terms of accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% confidence intervals (CIs).ResultsThe participants had a median age of 51 years and an interquartile range of 43–58 years. Regarding LR‐5 as a predictor of HCC, the accuracy results of the ACR LI‐RADS and modified LI‐RADS algorithms were 72.9 and 71.4%, respectively (P = .50). The sensitivity of both systems was the same (69.7%; 95% CI: 60.7–77.8%). Regarding LR‐M as a predictor of non‐HCC malignancy, the diagnostic performance of the algorithms was the same, with accuracy and sensitivity results of 76.4 and 73.3%, respectively (95% CI: 44.9–92.2%).ConclusionThe findings indicate that modified LI‐RADS had a moderate level of diagnostic performance for HCC in examinations using Sonazoid, which was comparable to ACR LI‐RADS.

Funder

National Natural Science Foundation of China

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3