Comparison of cervical length measured by pelvic organ prolapse quantification system and sonography

Author:

Tondro Anamag Farhad1ORCID,Noshad Iran Laleh2,Mousavi Sanaz2ORCID,Salehi‐Pourmehr Hanieh1ORCID,Bastani Parvin2ORCID

Affiliation:

1. Research Center for Evidence‐Based Medicine, Iranian EBM Centre: A Joanna Briggs Institute (JBI) Center of Excellence Tabriz University of Medical Sciences Tabriz Iran

2. Women's Reproductive Health Research Center Tabriz University of Medical Sciences Tabriz Iran

Abstract

AbstractBackgroundPelvic organ prolapse (POP) is associated with cervical elongation (CE). The presence of CE could affect the surgical approach for the patient. Cervical length measurement using the pelvic organ prolapse quantification system (POP‐Q) has poor accuracy in CE detection. We speculated that transvaginal sonography of the cervix could be an alternative method to assess the cervical length properly.AimsWe aimed to compare cervical length based on POP‐Q examination with transvaginal sonography.MethodsThis was a prospective observational study of 99 patients with POP symptoms. POP‐Q staging was performed, and a gynaecologist determined cervical length. Moreover, all women underwent transvaginal sonography, and cervical length was reported. We used the inter‐class correlation coefficient and Bland–Altman plot to assess agreement. We used Spearman or Pearson correlation to determine the relationship between measurements difference and age, body mass index (BMI), total vaginal length, and parity.ResultsOne‐sample t‐test showed a significant difference between cervical length measured by POP‐Q and sonography (mean difference 9.93, 95% CI 8.26–11.93, p value <.001). The inter‐class correlation coefficient was reported as 0.476 (95% CI 0.22–0.65). The Bland–Altman plot illustrated considerable disagreement. There was no statistically significant correlation between measurement discrepancy and age, BMI, total vaginal length, or parity.ConclusionsThere is a significant discrepancy between the POP‐Q system and sonography in cervical length measurement. Given the importance of CE detection in choosing an appropriate surgical approach, it seems reasonable to repeat the measurement using alternative methods like sonography.

Funder

Tabriz University of Medical Sciences

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3