Technical note: Does scan resolution or downsampling impact the analysis of trabecular bone architecture?

Author:

Lukova Andrea12ORCID,Dunmore Christopher J.1ORCID,Tsegai Zewdi J.3ORCID,Bachmann Sebastian4,Synek Alexander4,Skinner Matthew M.2

Affiliation:

1. Skeletal Biology Research Centre, School of Anthropology and Conservation University of Kent Canterbury UK

2. Human Origins Max Planck Institute for Evolutionary Anthropology Leipzig Germany

3. Department of Organismal Biology and Anatomy University of Chicago Chicago Illinois USA

4. Computatioal Biomechanics Institute of Lightweight Design and Structural Biomechanics Wien Austria

Abstract

AbstractThe “gold standard” for the assessment of trabecular bone structure is high‐resolution micro‐CT. In this technical note, we test the influence of initial scan resolution and post hoc downsampling on the quantitative and qualitative analysis of trabecular bone in a Gorilla tibia. We analyzed trabecular morphology in the right distal tibia of one Gorilla gorilla individual to investigate the impact of variation in voxel size on measured trabecular variables. For each version of the micro‐CT volume, trabecular bone was segmented using the medical image analysis method. Holistic morphometric analysis was then used to analyze bone volume (BV/TV), anisotropy (DA), trabecular thickness (Tb.Th), spacing (Tb.Sp), and number (Tb.N). Increasing voxel size during initial scanning was found to have a strong impact on DA and Tb.Th measures, while BV/TV, Tb.Sp, and Tb.N were found to be less sensitive to variations in initial scan resolution. All tested parameters were not substantially influenced by downsampling up to 90 μm resolution. Color maps of BV/TV and DA also retained their distribution up to 90 μm. This study is the first to examine the effect of variation in micro‐CT voxel size on the analysis of trabecular bone structure using whole epiphysis approaches. Our results indicate that microstructural variables may be measured for most trabecular parameters up to a voxel size of 90 μm for both scan and downsampled resolutions. Moreover, if only BV/TV, Tb.Sp or Tb.N is measured, even larger voxel sizes might be used without substantially affecting the results.

Publisher

Wiley

Reference64 articles.

1. Quantitative and comparative visualization applied to cosmological simulations;Ahrens J.;Journal of Physics: Conference Series,2006

2. In vivo trabecular bone morphologic and mechanical relationship using high‐resolution 3‐T MRI;Alberich‐Bayarri A.;American Journal of Roentgenology,2008

3. A computational framework for canonical holistic morphometric analysis of trabecular bone;Bachmann S.;Scientific Reports,2022

4. A Wolff in sheep's clothing: Trabecular bone adaptation in response to changes in joint loading orientation;Barak M. M.;Bone,2011

5. Cortical bone distribution in the femoral neck of Paranthropus robustus;Cazenave M.;Journal of Human Evolution,2019

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3