A silent echo‐planar spectroscopic imaging readout with high spectral bandwidth MRSI using an ultrasonic gradient axis

Author:

Versteeg Edwin1ORCID,Nam Kyung Min1ORCID,Klomp Dennis W. J.1,Bhogal Alex A.1ORCID,Siero Jeroen C. W.12ORCID,Wijnen Jannie P.1ORCID

Affiliation:

1. Center for Image Sciences, Department of Radiology University Medical Center Utrecht Utrecht The Netherlands

2. Spinoza Centre for Neuroimaging Amsterdam Netherlands

Abstract

AbstractPurposeWe present a novel silent echo‐planar spectroscopic imaging (EPSI) readout, which uses an ultrasonic gradient insert to accelerate MRSI while producing a high spectral bandwidth (20 kHz) and a low sound level.MethodsThe ultrasonic gradient insert consisted of a single‐axis (z‐direction) plug‐and‐play gradient coil, powered by an audio amplifier, and produced 40 mT/m at 20 kHz. The silent EPSI readout was implemented in a phase‐encoded MRSI acquisition. Here, the additional spatial encoding provided by this silent EPSI readout was used to reduce the number of phase‐encoding steps. Spectroscopic acquisitions using phase‐encoded MRSI, a conventional EPSI‐readout, and the silent EPSI readout were performed on a phantom containing metabolites with resonance frequencies in the ppm range of brain metabolites (0–4 ppm). These acquisitions were used to determine sound levels, showcase the high spectral bandwidth of the silent EPSI readout, and determine the SNR efficiency and the scan efficiency.ResultsThe silent EPSI readout featured a 19‐dB lower sound level than a conventional EPSI readout while featuring a high spectral bandwidth of 20 kHz without spectral ghosting artifacts. Compared with phase‐encoded MRSI, the silent EPSI readout provided a 4.5‐fold reduction in scan time. In addition, the scan efficiency of the silent EPSI readout was higher (82.5% vs. 51.5%) than the conventional EPSI readout.ConclusionsWe have for the first time demonstrated a silent spectroscopic imaging readout with a high spectral bandwidth and low sound level. This sound reduction provided by the silent readout is expected to have applications in sound‐sensitive patient groups, whereas the high spectral bandwidth could benefit ultrahigh‐field MR systems.

Funder

HORIZON EUROPE Marie Sklodowska-Curie Actions

Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Eurostars

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3