Stability of glycated haemoglobin (HbA1c) measurements from whole blood samples kept at −196°C for seven to eight years in The Malaysian Cohort study

Author:

Abdullah Noraidatulakma1ORCID,Goh Ying‐Xian1ORCID,Othman Raihannah1,Ismail Norliza1,Jalal Nazihah1,Wan Sallam Wan Ahmad Faisal1,Husin Nurul Faeizah1,Shafie Ahmad Syafiq1,Awang Afifah1,Kamaruddin Mohd Arman1,Jamal Rahman1

Affiliation:

1. UKM Medical Molecular Biology Institute (UMBI) Universiti Kebangsaan Malaysia Kuala Lumpur Malaysia

Abstract

AbstractObjectiveGlycated haemoglobin (HbA1c) is a standard indication for screening type 2 diabetes that also has been widely used in large‐scale epidemiological studies. However, its long‐term quality (in terms of reproducibility) stored in liquid nitrogen is still unknown. This study is aimed to evaluate the stability and reproducibility of HbA1c measurements from frozen whole blood samples kept at −196°C for more than 7 years.MethodsA total of 401 whole blood samples with a fresh HbA1c measurement were randomly selected from The Malaysian Cohort's (TMC) biobank. The HbA1c measurements of fresh and frozen (stored for 7–8 years) samples were assayed using different high‐performance liquid chromatography (HPLC) systems. The HbA1c values of the fresh samples were then calculated and corrected according to the later system. The reproducibility of HbA1c measurements between calculated‐fresh and frozen samples was assessed using a Passing‐Bablok linear regression model. The Bland–Altman plot was then used to evaluate the concordance of HbA1c values.ResultsThe different HPLC systems highly correlated (r = 0.99) and agreed (ICC = 0.96) with each other. Furthermore, the HbA1c measurements for frozen samples strongly correlate with the corrected HbA1c values of the fresh samples (r = 0.875) with a mean difference of −0.02 (SD: −0.38 to 0.38). Although the mean difference is small, discrepancies were observed within the diabetic and non‐diabetic samples.ConclusionThese data demonstrate that the HbA1c measurements between fresh and frozen samples are highly correlated and reproducible.

Funder

Ministry of Higher Education, Malaysia

Universiti Kebangsaan Malaysia

Publisher

Wiley

Subject

Microbiology (medical),Biochemistry (medical),Medical Laboratory Technology,Clinical Biochemistry,Public Health, Environmental and Occupational Health,Hematology,Immunology and Allergy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3