Humoral immunity trends in a hemodialysis cohort following SARS‐CoV‐2 mRNA booster: A cohort study

Author:

Goggins Eibhlin1ORCID,Sharma Binu1,Ma Jennie Z.12,Gautam Jitendra1,Bowman Brendan1

Affiliation:

1. Division of Nephrology University of Virginia School of Medicine Charlottesville Virginia USA

2. Public Health Sciences University of Virginia School of Medicine Charlottesville Virginia USA

Abstract

AbstractBackground and AimsPatients with end stage kidney disease on hemodialysis are vulnerable to SARS‐CoV‐2 infection. Current guidelines recommend boosters of SARS‐CoV‐2 mRNA‐based vaccines. The long‐term humoral response of hemodialysis patients infected with SARS‐CoV‐2 after receiving a booster of SARS‐CoV‐2 mRNA‐based vaccines has been incompletely characterized. Here, we determined the long‐term humoral response of hemodialysis patients to two and three doses of the Pfizer BioNTech (BNT162b2) mRNA SARS‐CoV‐2 vaccine and investigated the effect of postbooster SARS‐CoV‐2 infection on antibody levels over time.MethodsSamples were collected on a monthly basis and tested for anti‐SARS‐CoV‐2 antibodies against anti‐spike S1 domain. Thirty‐five hemodialysis patients were enrolled in the original study and 27 of these received a booster. Patients were followed up to 6 months after the first two doses and an additional 7 months after the third BNT162b2 dose. Results are presented as the internationally harmonized binding antibody units (BAU/mL).ResultsAntibody level significantly increased from prebooster to 2 weeks postbooster, with a median [25th, 75th percentile] rise from 52.72 [28.55, 184.7] to 6216 [3806, 11,730] BAU/mL in the total population. Of patients with a negative or borderline detectable antibody level 6 months after vaccination who received a third dose, 89% developed positive antibody levels 2 weeks postbooster. Postbooster antibody levels declined an average rate of 29% per month in infection‐naïve patients. Antibody levels spiked in patients infected with SARS‐CoV‐2 after receiving a booster but declined rapidly. No patients infected postbooster required hospitalization.ConclusionsA third dose of BNT162b2 restores antibody levels to high levels in dialysis patients but levels decline over time. A third dose did not necessarily prevent infection, but no patients suffered severe infection or required hospitalization. SARS‐CoV‐2 recovered patients appear to have a blunted rise in antibody levels after a third dose. Although patients infected with SARS‐CoV‐2 postbooster had an immediate spike in antibody levels, these declined over time.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3