Immunoreactivity of TTF‐1, GATA‐3, CEA, and p16/Ki67 cocktail in Cellprep®‐processed control samples: Comparison of long‐term storage in vials and slides

Author:

Ryu Ayumi123ORCID,Honma Keiichiro1ORCID,Umeno Yoshimi12,Uefuji Fusayo12,Muramatsu Takako12,Nishimura Sanako12,Tanada Satoshi12,Yamamoto Takashi2,Nagata Shigenori1ORCID,Yamasaki Tomoyuki2,Ohue Masayuki3

Affiliation:

1. Department of Diagnostic Pathology and Cytology Osaka International Cancer Institute Osaka Japan

2. Department of Clinical Laboratory Osaka International Cancer Institute Osaka Japan

3. Department of Oncology, Graduate School of Medicine Osaka University Osaka Japan

Abstract

AbstractIntroductionCellprep® (CP) is a novel liquid‐based cytology (LBC) system. This study aimed to assess the immunoreactivity of control samples stored long‐term under two storage conditions using CP.MethodsThe immunoreactivity in control samples was evaluated under two sample storage conditions: CP vial storage at room temperature (RT: 20–25°C) and CP slide storage in a refrigerator (2–6°C). Clinical samples as controls (total: positive/negative) were immunostained using thyroid transcription factor‐1 (TTF‐1) (20: 14/6), GATA binding protein 3 (GATA‐3) (13: 10/3), carcinoembryonic antigen (CEA) (23: 15/8), and the p16/Ki67 cocktail (20: 12/8) markers. The first immunocytochemistry (ICC) was performed within 1 month using CP vials stored at RT. Samples stored in CP vials and on CP slides were used for the second (within 3–6 months) and third (within 6–11 months) ICCs. Compared with the first ICC, the concordance of immunoreactivity for the second and third ICCs was evaluated using the weighted kappa coefficient.ResultsFor TTF‐1, CEA, and the p16/Ki67 cocktail markers, ICC controls had stable immunoreactivity for a minimum of 6 months when samples were stored in CP vials (kappa coefficients >0.8), whereas for GATA‐3, they were for 3 months. On CP slides, only for the p16/Ki67 cocktail, ICC controls had stable immunoreactivity for at least 3 months (kappa coefficient >0.8).ConclusionClinical samples as ICC controls revealed consistently more stable immunoreactivity in CP vials than on CP slides for TTF‐1, GATA‐3, CEA, and the p16/Ki67 cocktail markers.

Publisher

Wiley

Subject

General Medicine,Histology,Pathology and Forensic Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3