Mechanical strength of stock and custom abutments as original and aftermarket components after thermomechanical aging

Author:

Pol Christiaan W. P.1ORCID,Cune Marco S.23,Raghoebar Gerry M.4,Naves Lucas Z.2,Meijer Henny J. A.24ORCID

Affiliation:

1. Department of Integrated Dentistry, Dental School, University Medical Center Groningen University of Groningen Groningen The Netherlands

2. Department of Restorative Dentistry, Dental School, University Medical Center Groningen University of Groningen Groningen The Netherlands

3. Department of Oral and Maxillofacial Surgery Prosthodontics and Special Dental Care, St. Antonius hospital Nieuwegein Nieuwegein The Netherlands

4. Department of Oral and Maxillofacial Surgery, University Medical Center Groningen University of Groningen Groningen The Netherlands

Abstract

AbstractObjectivesThe study aimed to assess the impact on the mechanical strength and failure patterns of implant‐abutment complexes of choosing different abutment types, designs and manufacturers, aiding in selecting the optimal restorative solution. Stock and custom abutments from original and aftermarket suppliers were subjected to thermomechanical aging.Material and MethodsStock and custom abutments from the implant manufacturer (original) and a aftermarket supplier (nonoriginal) were connected to identical implants with internal connection. Custom abutments were designed in a typical molar and premolar design, manufactured using the workflow from the respective suppliers. A total of 90 implants (4 mm diameter, 3.4 mm platform, 13 mm length) equally divided across 6 groups (three designs, two manufacturers) underwent thermo‐mechanical aging according to three different regimes, simulating five (n = 30) or 10 years (n = 30) of clinical function, or unaged control (n = 30). Subsequently, all samples were tested to failure.ResultsDuring aging, no failures occurred. The mean strength at failure was 1009N ± 171, showing significant differences between original and nonoriginal abutments overall (−230N ± 27.1, p < .001), and within each abutment type (p = .000), favoring original abutments. Aging did not significantly affect the failure load, while the type of abutment and manufacturer did, favoring original and custom‐designed abutments. The most common failure was implant bending or deformation, significantly differing between original and nonoriginal abutments and screws. All failure tests resulted in clinically unsalvageable implants and abutments.ConclusionsWithin the limitations of this study, original abutments exhibited a higher mechanical strength compared to the nonoriginal alternative, regardless of the amount of simulated clinical use. Similarly, custom abutments showed higher mechanical strength compared to stock abutments. However, mechanical strength in all abutments tested was higher than average chewing forces reported in literature, thus components tested in this study can be expected to perform equally well in clinical situations without excessive force.

Funder

ZonMw

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3