Defining field output factors in small fields based on dose area product measurements: A feasibility study

Author:

Jurczak Julien12,Rapp Benjamin1,Bordy Jean‐Marc1,Josset Stephanie3,Dufreneix Stephane13

Affiliation:

1. CEA, List Laboratoire National Henri Becquerel (LNE‐LNHB) Palaiseau France

2. Medical Physics Department Institut Curie Paris France

3. Medical Physics Department Institut de Cancérologie de l'Ouest Saint‐Herblain, Angers France

Abstract

AbstractBackgroundDose area product in water (DAPw) in small fields relies on the use of detectors with a sensitive area larger than the irradiation field. This quantity has recently been used to establish primary standards down to 5 mm field size, with an uncertainty smaller than 0.7%. It has the potential to decrease the uncertainty related to field output factors, but is not currently integrated into treatment planning systems.PurposeThis study aimed to explore the feasibility of converting DAPw into a point dose in small fields by determining the volume averaging correction factor. By determining the field output factors, a comparison between the so‐called “DAPw to point dose” approach and the IAEA TRS483 methodology was performed.MethodDiodes, microdiamonds, and a micro ionization chamber were used to measure field output factors following the IAEA TRS483 methodology on two similar linacs equipped with circular cones down to 6 mm diameter. For the “DAPw to point dose” approach, measurements were performed with a dedicated and built‐in‐house 3 cm diameter plane‐parallel ionization chamber calibrated in terms of DAPw in the French Primary Dosimetry Standards Laboratory LNE‐LNHB. Beam profile measurements were performed to generate volume averaging correction factors enabling the conversion of an integral DAPw measurement into a point dose and the determination of the field output factors. Both sets of field output factors were compared.ResultsAccording to the IAEA TRS483 methodology, field output factors were within ±3% for all detectors on both linacs. Large variations were observed for the volume averaging correction factors with a maximum spread between the detectors of 26% for the smallest field size. Consequently, deviations of up to 15% between the “IAEA TRS483” and the “DAPw to point dose” methodologies were found for the field output factor of the smallest field size. This was attributed to the difficulty in accurately determining beam profiles in small fields.ConclusionAlthough primary standards associated with small uncertainties can be established in terms of DAPw in a primary laboratory, the “DAPw to point dose” methodology requires volume averaging correction to derive a field output factor from DAPw measurements. None of the point detectors studied provided satisfactory results, and additional work using other detectors, such as film, is still required to allow the transfer of a DAP primary standard to users in terms of absorbed point dose.

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3