Intra‐ and inter‐fractional variations of tumors with fiducial markers measured using respiratory‐correlated computed tomography images for respiratory gated lung stereotactic body radiation therapy

Author:

Manabe Yuki1,Shiinoki Takehiro1ORCID,Fujimoto Koya1,Ueda Kazushi1,Karita Masako1,Ono Taiki1,Kajima Miki1,Tanaka Hidekazu1

Affiliation:

1. Department of Radiation Oncology Yamaguchi University Graduate School of Medicine Ube Yamaguchi Japan

Abstract

AbstractPurposeThis study evaluated the intra‐ and inter‐fractional variation of tumors with fiducial markers (FMs), relative to the tumor‐FM distance, to establish how close an FM should be inserted for respiratory‐gated stereotactic body radiation therapy (RG‐SBRT).MethodsForty‐five lung tumors treated with RG‐SBRT were enrolled. End‐expiratory computed tomography (CT) (CTplan) and four‐dimensional‐CT (4D‐CT) scans were obtained for planning. End‐expiratory CT (CTfr) scanning was performed before each fraction. The FMs were divided into two groups based on the median tumor‐FM distance in the CTplan (Dp). For the intra‐fractional variation, the correlations between the corresponding tumor and FM intra‐fractional motions, defined as the centroid coordinates of those in each 0–90% phase, with the 50% phase of 4D‐CT as the origin, were calculated in the left‐right, anterior‐posterior, and superior‐inferior directions. Furthermore, the maximum difference in the tumor‐FM distance in each phase of 4D‐CT scan, based on those in the 50% phase of 4D‐CT scan (Dmax), was obtained. Inter‐fractional variation was defined as the maximum distance between the tumors in CTplan and CTfr, when the CT scans were fused based on each FM or vertebra.ResultsThe median Dp was 26.1 mm. While FM intra‐fractional motions were significantly and strongly correlated with the tumor intra‐fractional motions in only anterior‐posterior and superior‐inferior directions for the Dp > 26 mm group, they were significantly and strongly correlated in all directions for the Dp ≤ 26 mm group. In all directions, Dmax values of the Dp ≤ 26 mm group were lower than those of the Dp > 26 mm group. The inter‐fractional variations based on the Dp ≤ 26 mm were smaller than those on the Dp > 26 mm and on the vertebra in all directions.ConclusionsRegarding intra‐ and inter‐fractional variation, FMs for Dp ≤ 26 mm can increase the accuracy for RG‐SBRT.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3