Impact of respiratory motion on 18F‐FDG PET radiomics stability: Clinical evaluation with a digital PET scanner

Author:

Chen Yu‐Hung123,Kan Kuo‐Yi4,Liu Shu‐Hsin13,Lin Hsin‐Hon56,Lue Kun‐Han3

Affiliation:

1. Department of Nuclear Medicine Hualien Tzu Chi Hospital Buddhist Tzu Chi Medical Foundation Hualien Taiwan

2. School of Medicine College of Medicine Tzu Chi University Hualien Taiwan

3. Department of Medical Imaging and Radiological Sciences Tzu Chi University of Science and Technology Hualien Taiwan

4. Department of Nuclear Medicine Fu Jen Catholic University Hospital New Taipei City Taiwan

5. Department of Medical Imaging and Radiological Sciences College of Medicine Chang Gung University Taoyuan Taiwan

6. Department of Nuclear Medicine Chang Gung Memorial Hospital Linkou Taiwan

Abstract

AbstractPurpose18F‐FDG PET quantitative features are susceptible to respiratory motion. However, studies using clinical patient data to explore the impact of respiratory motion on 18F‐FDG PET radiomic features are limited. In this study, we investigated the impact of respiratory motion on radiomics stability with clinical 18F‐FDG PET images using a data‐driven gating (DDG) algorithm on the digital PET scanner.Materials and MethodsA total of 101 patients who underwent oncological 18F‐FDG PET scans were retrospectively included. A DDG algorithm combined with a motion compensation technique was used to extract the PET images with respiratory motion correction. 18F‐FDG‐avid lesions from the thorax to the upper abdomen were analyzed on the non‐DDG and DDG PET images. The lesions were segmented with a 40% threshold of the maximum standardized uptake. A total of 725 radiomic features were computed from the segmented lesions, including first‐order, shape, texture, and wavelet features. The intraclass correlation coefficient (ICC) and coefficient of variation (COV) were calculated to evaluate feature stability. An ICC above 0.9 and a COV below 5% were considered high stability.ResultsIn total, 168 lesions with and without respiratory motion correction were analyzed. Our results indicated that most 18F‐FDG PET radiomic features are sensitive to respiratory motion. Overall, only 27 out of 725 (3.72%) radiomic features were identified as highly stable, including one from the first‐order features (entropy), one from the shape features (sphericity), four from the gray‐level co‐occurrence matrix features (normalized and unnormalized inverse difference moment, joint entropy, and sum entropy), one from the gray‐level run‐length matrix features (run entropy), and 20 from the wavelet filter‐based features.ConclusionRespiratory motion has a significant impact on 18F‐FDG PET radiomics stability. The highly stable features identified in our study may serve as potential candidates for further applications, such as machine learning modeling.

Funder

Buddhist Tzu Chi Medical Foundation

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3