Impact of the failure of initial insertion of a peripheral intravascular catheter on the development of adverse events in patients admitted to the intensive care unit from the emergency room: A post hoc analysis of the AMOR‐VENUS study

Author:

Kishihara Yuki1ORCID,Yasuda Hideto12ORCID,Kashiura Masahiro1ORCID,Moriya Takashi1ORCID,Shinzato Yutaro1,Kotani Yuki3,Kondo Natsuki4ORCID,Sekine Kosuke5,Shime Nobuaki6,Morikane Keita7,

Affiliation:

1. Department of Emergency and Critical Care Medicine Jichi Medical University Saitama Medical Center Saitama Japan

2. Department of Clinical Research Education and Training Unit Keio University Hospital Clinical and Translational Research Center (CTR) Tokyo Japan

3. Department of Intensive Care Medicine Kameda Medical Center Chiba Japan

4. Department of Intensive Care Medicine Chiba Emergency Medical Center Chiba‐shi Japan

5. Department of Medical Engineer Kameda Medical Center Chiba Japan

6. Department of Emergency and Critical Care Medicine, Graduate School of Biomedical and Health Sciences Hiroshima University Hiroshima Japan

7. Division of Clinical Laboratory and Infection Control Yamagata University Hospital Yamagata Japan

Abstract

AbstractAimTo investigate an association between failure of initial peripheral intravascular catheter (PIVC) insertion and adverse events in patients admitted to the intensive care unit (ICU) from the emergency room (ER).MethodsThis study was a post hoc analysis of the AMOR‐VENUS study, a multicenter cohort study that included 22 institutions and 23 ICUs in Japan between January and March of 2018. Study participants included consecutive adult patients admitted to the ICU with PIVCs inserted in ICU during the study period exclusively from the ER. The primary outcome was adverse events. Adverse events were composite of arterial puncture, hematoma, extravasation, nerve injury, tendon injury, compartment syndrome, pain, redness, bad location, and effusion. Multivariate logistic regression analyses were performed to assess the association between adverse events and the failure of initial PIVC insertion.ResultsIn total, 363 patients and 1121 PIVCs were analyzed. Moreover, 199 catheters failed to insert properly, and 36 patients and 107 catheters experienced adverse events. After performing multivariate logistic regression analysis, there were statistically significant associations in the odds ratio (OR) and 95% confidence interval (CI) for the failure of initial insertion (OR, 1.66 [1.02–2.71]; p = 0.04).ConclusionFailure of initial insertion may be a risk factor for adverse events. We could potentially provide various interventions to avoid failure of initial PIVC insertion. For example, PIVC insertion could be performed by experienced practitioners.

Publisher

Wiley

Subject

Industrial and Manufacturing Engineering,Materials Science (miscellaneous),Business and International Management

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3