Affiliation:
1. Faculty of Physics and Applied Computer Science AGH‐UST University of Science and Technology Krakow Poland
Abstract
AbstractElemental composition of air particulate matter samples was determined by energy dispersive x‐ray fluorescence technique utilizing in‐house constructed secondary target excitation system. The system, based on 3 kW Mo‐anode x‐ray tube with Ni and Mo secondary targets, was operated in air at atmospheric pressure. The sensitivities of the measurement system were determined for a number of elements in the atomic number range from Z = 13 to Z = 39 (K‐series characteristic radiation) and from Z = 44 to Z = 82 (L‐series characteristic radiation). The results of measurement of reference material samples confirmed that the in‐house constructed system is well suited for analysis of air particulate matter deposits on filter substrate with application of the thin‐layer sample model, with sufficiently good detection limits also for low‐Z elements such as Al, Si, P, S, and Cl.
Funder
Ministry of Science and Higher Education
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献